Variable level pump switches, Figure 1, Installation instructions

background image

Notice to iNstaller: instructions must remain with installation.

© Copyright 2011. All rights reserved.

reaD all iNstrUctioNs BeFore iNstalliNG - all aPPlicatioNs

Make sure the pump electrical supply circuit is equipped with fuses or circuit breakers of proper capacity. A separate branch circuit is recommended,

sized according to the National Electrical Code for the current shown on the pump name plate.

For YoUr ProtectioN alWaYs DiscoNNect PUMP FroM its PoWer soUrce BeFore HaNDliNG. Single phase pumps are supplied

with a 3-prong grounded plug to help protect you against the possibility of electrical shock.

Do Not UNDer aNY circUMstaNces reMoVe tHe GroUND PiN. The 3-prong plug must be inserted into a mating 3-prong grounded recep-

tacle. If the installation does not have such a receptacle, it must be changed to the proper type, wired and grounded in accordance with the National Electrical Code and

all applicable local codes and ordinances.

FIGURE 1

CORDS SECURED

"ON"

"OFF"

LEVEL

LEVEL

TO DISCHARGE

PIPE

RANGE PUMPING

FLOAT

CLAMPS

THE "ON" LEVEL IS

APPROXIMATELY 4"

ABOVE MOUNTING

LOCATION

THE "OFF" LEVEL IS

APPROXIMATELY 4"

BELOW MOUNTING

LOCATION

MECHANICAL FLOAT SWITCH

10-1964, 10-1965, 10-1966, 10-1967

CORDS SECURED

"ON"

"OFF"

LEVEL

LEVEL

TO DISCHARGE

PIPE

FLOAT

CLAMPS

NARROW ANGLE

FLOAT SWITCHES

RANGE PUMPING

sk308b

Clarus Environmental 10-0229, 10-0230, 10-1209, 10-1210, 10-1964, 10-1965, 10-1966 and 10-1967 Variable Level Pump Switches are designed for use with

the appropriate voltage and horsepower, nonautomatic, single phase, Clarus Environmental pumps.

Use 10-0229, 10-1209, 10-1964 and 10-1966 for 115V and 10-0230, 10-1210, 10-1965 and 10-1967 for 230V. All can be used as a control switch for a magnetic

or combination starter. Maximum temperature must not exceed 140°F. Note: UL Recognized and CSA approved. Note: Consult Clarus Environmental for controlling units over

1½ HP with a variable level pump switch.

iNstallatioN iNstrUctioNs

1. Decide the desired pumping range for your installation. (See Fig.

1.) Secure the float cable clamps to the discharge pipe at the

distance you desire. (See clamp detail in Fig. 6 on next page).

The float labeled “TOP” must be on top. (The cable clamps are

releasable, which permits readjustment and removal.)

Notice: Do not adjust “off’’ level below discharge on

pump.

2. Insert the piggyback plug from the switches into a standard grounded

outlet of proper voltage. For automatic operation plug the pump

directly into the piggyback plug. (Pump can be manually operated

by bypassing piggyback plug.) See Fig. 2.

Notice: For installation utilizing a watertight junction box or

similar connections, see Figure 3.

Notice: For installation as a control switch for magnetic or

combination starter, see Figure 4.

3. Securely tape or clamp both piggyback switch cord and pump cord

to the discharge pipe, clear of float operation. (See Fig. 1.) Excess

cord should be coiled and fastened to the discharge pipe.

4. Clean basin free of debris after installation.

5. Check and test your installation. Fill basin with water and allow pump to cycle to insure proper range and operation. Notice: For installation utilizing a Piggyback Float Switch

connection use Clarus Environmental Qwik-Box.

FIGURE 2

FIGURE 3

FIGURE 4

A) Remove (cut) Piggyback

Plug from Variable Level

Pump switch. Remove

approx. 3½” of cord

jacket and 1” insulation

from wires.

b) Wire switch into circuit as

shown.

C) Return to Instructions.

D) Installation must be in

agreement with the

National Electrical Code

and all local codes.

sk308C

PUMP PLUG

SWITCH PLUG

AUTOMATIC

OPERATION

MANUAL

OPERATION

sk308A

VARIABLE

LEVEL

PUMP

SWITCHES

sk378b

VARIABLE

LEVEL

PUMP

SWITCHES

Variable Level Pump Switches

sectioN: c6.00.043

CL0117

1111

Supersedes

New

3649 Cane Run Road . Louisville, KY 40211-1961

877-244-9340 . Fax: 877-414-4316

www.clarusenvironmental.com

®

®

INSTALLATION INSTRUCTIONS