Clarus Environmental Spider Valve User Manual
Installation instructions, Installation steps, Spider valve
Notice to iNstaller: instructions must remain with installation.
© Copyright 2013. All rights reserved.
FIGURE 1
SK2322
ALL WORK IN ACCORDANCE
WITH NEC AND ANY OTHER
STATE OR LOCAL CODES
SEPTIC TANK
STEP SYSTEM
24 OR 30 INCH
ACCESS RISER & LID
FILTERED
ALARM
WIRING
CONDUIT
TO OTHER TRENCHES
EFFLUENT
VALVE
SPIDER
CLARUS
FIGURE 1
TYPICAL GRAVITY
TRENCH
MANIFOLD
* The Distal Pressure selected will need to be added to the friction head and static head for the TDH.
Distal Pressure
Flow (GPM) per Orifice
Feet*
psi
5/32"
3/16"
7/32"
1/4"
9/32"
5/16"
11/32"
3/8"
3
1.30
0.52
0.75
1.03
1.34
1.70
2.09
2.53
3.01
4
1.73
0.60
0.87
1.18
1.55
1.96
2.42
2.92
3.48
5
2.16
0.68
0.97
1.32
1.73
2.19
2.70
3.27
3.89
6
2.60
0.74
1.07
1.45
1.89
2.40
2.96
3.58
4.26
SK2323
Installation Steps
1. Spider Valve
®
assembly must be
installed at the high point of the system
such that the effluent will gravity drain
from the valve to the disposal trenches.
Consult site plan and Figure 1.
2. At least 3' of distal pressure should be
maintained on the manifold to ensure
proper effluent splitting.
FIGURE 2
DETAIL "A"
1/2" FLEX PIPE
WITH GRAVEL
TOP OF MANIFOLD
FILL TO NEAR
DETAIL "A"
TRENCH
TO DISTRIBUTION
BASE
2" GRAVEL
2" MANIFOLD
PLACE WASHER INSIDE
UNIONS DURING FIELD ASSEMBLY
1/2 X 1 1/4
RED BUSHING
NOTE: For sizing help please consult Clarus
Environmental at 1-800-928-7867 or use the Spider
Valve
®
Orifice Sizing Tool to help design your onsite
system at www.clarusenvironmental.com
Spider Valve
®
sectioN: c4.00.013
CL0078
0813
Supersedes
0112
3649 Cane Run Road • Louisville, KY 40211-1961
800-928-7867 • Fax: 502-774-3624
www.clarusenvironmental.com
®
®