INSTALLATION INSTRUCTIONS

Clarus 5050 Series Recirculating Float & Splitter Valves

© Copyright 2014. All rights reserved.

INSTALLATION INSTRUCTIONS AND PREINSTALLATION CHECKLIST

1. Inspect materials upon delivery. Occasionally, products

are damaged during shipment. If materials are damaged,

contact your dealer prior to installation.

2. Read the relevant literature and installation instructions

carefully to become familiar with the product and proper

installation procedures.

3. The use of a septic tank effluent filter is strongly

recommended in order to protect downstream

components from accumulating solids.

CAUTION

All installations must comply with

applicable electrical and plumbing codes, including,

but not limited to, National Electrical Code, local,

regional, and/or state codes, etc.

CAUTION

The splitter valve must be level across the outlets.

CAUTION

Be sure the disposal pipe does not settle after

the splitter valve is installed.

Figure 1 5050-0002

Recirculating Float Valve

Figure 2 5050-0003 Splitter Valve

Part Number Description

Minimum Riser Diameter

5050-0001

Recirculating Float Valve and

Splitter Valve Combo

36"

5050-0002

Recirculating Float Valve

24"

5050-0003

Splitter Valve

24"

5080-0011

4" Pipe Seal

N/A