Troubleshooting – CHAMPION EUCC Series User Manual
Page 26

18
Troubleshooting
Troubleshooting
On occasion your machine may not operate as expected.
Use	the	checklist	below	before	you	decide	that	a	mechanical	or	electrical	failure	has	occurred.
Checklist
	 1.	 	 are	the	main	disconnect	switches,	breakers,	or	motor	overloads	turned	ON?
	 2.	 	 are	the	main	water	and	steam	supplies	turned	ON?
	 3.	 	 are	the	drain	valves	closed?
	 4.	 	 are	the	spray	pipes	and	rinse	nozzles	clean?
	 5.	 	 are	the	spray	pipes	in	the	proper	locations?
	 6.	 	 are	the	pump	intakes	clean?
	 7.	 	 are	the	scrap	screens	clean	and	in	place?
	 8.	 	 are	the	thermostats	correctly	adjusted?
	 9.	 	 are	the	high	limit	temperature	thermostats	reset?
	 10.	 	 are	the	doors	fully	closed?
	 11.			 	are	the	conveyor	shut-off	and	drive	assemblies	in	operating	condition?
	 12.	 	 are	the	chemical	supplies	adequately	filled?
If	a	problem	still	exists	after	verifying	the	checklist,	refer	to	the	following
CONDITION
CAUSE
SOLUTION
Conveyor will not run
Door not closed ................................... Make sure doors are fully closed
Door safety switch faulty .................... Contact your service agency
Start switch faulty ............................... Contact your service agency
Main switch OFF ................................ Check disconnect
Control panel power switch OFF ........ Flip switch ON
Conveyor shut-off shelf operated........ Move shelf toward tunnel of machine
Motor overload protector tripped ........ Reset overload in control cabinet
Green start button not pressed ............ Press green start button