8

SM1700

Pneumatic

Center Punch

Tool

1.

For best results and proper functioning of the SM1700 air tool, a filter / lubricator must be
used on the air supply or in line within 30 feet of the air tool. The warranty is voided if a
filter / lubricator is not used.

2.

Before using air tool, check to see that the blade and backing plate on the CP head are fully
tensioned. Loose bolts can easily cause breakage of blade and backing plate.

3.

Clean gripper occasionally. Particles and dirt on the gripper lever can cause it to slip off the
clamp tail. To remove gripper lever, loosen set screw in the head assembly from underneath
the block and tap out pin.

4.

The BAND-IT SM1700 Air Tool, although durable, does need periodic maintenance and
repair. The frequency of significant repairs can be greatly reduced by simply following
regular preventative maintenance such as maintaining tension on fasteners, proper
lubrication and not “free cycling” the tool without tensioning clamps.

Preventative
Maintenance

Frequency

Component

Check

Daily

Tool and tool head

Check for and tighten all fasteners.

Filter / Lubricator

Check for build-up of dirt, etc. Check for contaminated or
discolored lubricant.

Check for low lubricant. Refill with DTE 24 hydraulic oil. Set
drip rate to 1 drop each 10-25 cycles.

Every 2,000 clamps

Gripper

Check for build-up of dirt, etc., in teeth. Remove and clean.
Replace as necessary with new gripper kit.

Every 5,000 clamps

Cutter Blade and
Backing Plate

Rotate both parts. If parts have been rotated once before,
replace both as a kit.

Every 10,000 clamps

Tool Head

Return head to BAND-IT for service.

Every 6 Months

Cylinder

Check for build-up of dirt, contaminants on piston rod seals.
Clean exterior with soap and warm water.

Tripper Plate

Check for build-up of dirt, contaminants, etc. Clean and
apply lubricant.

Air Exhaust Mufflers

Check for build-up of dirt, contaminants, etc. Remove and
clean with non-flammable degreaser.

Preventative Maintenance Schedule