S75099 Pneumatic

Junior Clamp

Application Tool

4.

Setting Pull-up Pressure: Pull the identified regulator knob and turn clockwise to reach
pull-up pressure. Approach pressure setting from below by increasing pressure. Many
factors should be considered when choosing the correct operating setting for the tool.
The fitting design as well as the type, thickness and durometer of the hose material must
be considered when setting the correct pressures for your assembly.

5.

Holding Pressure reflects a lower pressure designed to allow the hose assembly to be
rolled up in preparation for setting the lock with the shearing or cutting action on the clamp
tail. A setting too low will cause difficulty in shearing the clamp tail and leaving an
excessive burr on the buckle at the point of lock. A setting too high may cause the clamp
tail to

“pop” free of the band gripper, cause the lock to slip back under the buckle or cause

a sudden jolt to the S75099 tool.

6.

Setting Holding Pressure: Cycle the tool, holding the foot pedal in the toe forward position.
The tool will reach pull-up tension and kick down to a holding pressure. Read the gauge
and repeat the cycle turning the holding regulator clockwise to raise pressure or counter
clockwise to lower pressure. Allow the tool to settle after each cycle before reading the
value on the gauge.

7.

Check pressure setting by cycling tool until hold pressure gauge stops.

8.

Reset tool by depressing heel end of foot pedal. Remove foot.

9. Repeat steps 2, 4, 6, and 7. At pressure kick down, verify all settings and adjust if

necessary. Lock settings in place.

Setting Controls
and Tool
Operation

Clamp Width

Inch

Pull Up

Pressure

(PSI)

Holding

Pressure

(PSI)

Speed

Control

Setting

Pull Up

Pressure

(PSI)

Holding

Pressure

(PSI)

Speed

Control

Setting

Pull Up

Pressure

(PSI)

Holding

Pressure

(PSI)

Speed

Control

Setting

1/4" (6.4mm)

15

4 Blue

15

4 Blue

NA

NA

NA

3/8" (7.5mm)

25

5 White

20

5 White

25

6 Blue

1/2" (12.7mm)

40

6 White

35

6 White

40

7 White

5/8" (15.9mm)

50

7 Red

40

7 Red

50

8 White

3/4" (19.1mm)

60

8 Red

50

8 Red

60

9 Red

Galvanized Carbon Steel

316 Stainless Steel

201 Stainless Steel

Guide for Operating Pressures for the S75099 Air tool

Rule: Allow air to completely exhaust between each stage of the tools cycle. Failure