Setting controls and tool operation – BAND-IT S75099 Pneumatic Junior Clamp Application Tool User Manual
Page 8
Document# P36687 Rev. I
© Copyright
BAND-IT-IDEX, Inc. 2013
All rights reserved
www.BAND-IT-IDEX.com
BAND-IT-IDEX, Inc.
A Unit of IDEX Corporation
4799 Dahlia Street Denver,
CO 80216-3070 USA
P: 1-800-525-0758 F: 1-800-624-3925
8
S75099 Pneumatic
Junior Clamp
Application Tool
4.
Setting Pull-up Pressure: Pull the identified regulator knob and turn clockwise to reach
pull-up pressure. Approach pressure setting from below by increasing pressure. Many
factors should be considered when choosing the correct operating setting for the tool.
The fitting design as well as the type, thickness and durometer of the hose material must
be considered when setting the correct pressures for your assembly.
5.
Holding Pressure reflects a lower pressure designed to allow the hose assembly to be
rolled up in preparation for setting the lock with the shearing or cutting action on the clamp
tail. A setting too low will cause difficulty in shearing the clamp tail and leaving an
excessive burr on the buckle at the point of lock. A setting too high may cause the clamp
tail to
“pop” free of the band gripper, cause the lock to slip back under the buckle or cause
a sudden jolt to the S75099 tool.
6.
Setting Holding Pressure: Cycle the tool, holding the foot pedal in the toe forward position.
The tool will reach pull-up tension and kick down to a holding pressure. Read the gauge
and repeat the cycle turning the holding regulator clockwise to raise pressure or counter
clockwise to lower pressure. Allow the tool to settle after each cycle before reading the
value on the gauge.
7.
Check pressure setting by cycling tool until hold pressure gauge stops.
8.
Reset tool by depressing heel end of foot pedal. Remove foot.
9. Repeat steps 2, 4, 6, and 7. At pressure kick down, verify all settings and adjust if
necessary. Lock settings in place.
Setting Controls
and Tool
Operation
Clamp Width
Inch
Pull Up
Pressure
(PSI)
Holding
Pressure
(PSI)
Speed
Control
Setting
Pull Up
Pressure
(PSI)
Holding
Pressure
(PSI)
Speed
Control
Setting
Pull Up
Pressure
(PSI)
Holding
Pressure
(PSI)
Speed
Control
Setting
1/4" (6.4mm)
15
4 Blue
15
4 Blue
NA
NA
NA
3/8" (7.5mm)
25
5 White
20
5 White
25
6 Blue
1/2" (12.7mm)
40
6 White
35
6 White
40
7 White
5/8" (15.9mm)
50
7 Red
40
7 Red
50
8 White
3/4" (19.1mm)
60
8 Red
50
8 Red
60
9 Red
Galvanized Carbon Steel
316 Stainless Steel
201 Stainless Steel
Guide for Operating Pressures for the S75099 Air tool
Rule: Allow air to completely exhaust between each stage of the tools cycle. Failure
to let air completely exhaust may result in clamps not pulling up tight.