beautypg.com

Air system requirements – BAND-IT S75099 Pneumatic Junior Clamp Application Tool User Manual

Page 5

background image

Document# P36687 Rev. I

© Copyright

BAND-IT-IDEX, Inc. 2013

All rights reserved

www.BAND-IT-IDEX.com

BAND-IT-IDEX, Inc.

A Unit of IDEX Corporation

4799 Dahlia Street Denver,

CO 80216-3070 USA

P: 1-800-525-0758 F: 1-800-624-3925

5

S75099 Pneumatic

Junior Clamp

Application Tool

Important: For proper tool performance, air requirements for S75099 should be:

Line Pressure

– 100 psi minimum,125 psi maximum (689 – 862 kPa)

Volume - should be 3-5 CFM

Air Delivery system -

¼” minimum diameter airline with a ¼” N.P.T. connection.

Filtration

– Follow typical filtration requirements of air operated equipment. Standard filtering

systems should be located no further than 30

’ from this tool in addition to the

supplemental system supplied at the back of the tool as shown below. This BAND-IT
supplied system includes a filter and lubricator. Lubricator should be refilled with DTE
24 hydraulic oil. The oil drip-rate can be verified by repeated full cycling the tool. One
drop should fall in the sight glass within 10-25 cycles. Excess oil will not benefit tool life
and may lead to blockage of air mufflers and a dirty environment.

View of the back side of the S75099 showing the
supplemental filtering and lubrication system as well as
the

¼” N.P.T. air connection with typical quick connect

coupling.

Air System
Requirements

Serial #
decal
location

Warning:

The lubricator should be refilled with DTE 24 hydraulic

oil only. The use of other oils may cause damage to the system.