Air system requirements – BAND-IT S75099 Pneumatic Junior Clamp Application Tool User Manual
Page 5
Document# P36687 Rev. I
© Copyright
BAND-IT-IDEX, Inc. 2013
All rights reserved
www.BAND-IT-IDEX.com
BAND-IT-IDEX, Inc.
A Unit of IDEX Corporation
4799 Dahlia Street Denver,
CO 80216-3070 USA
P: 1-800-525-0758 F: 1-800-624-3925
5
S75099 Pneumatic
Junior Clamp
Application Tool
Important: For proper tool performance, air requirements for S75099 should be:
Line Pressure
– 100 psi minimum,125 psi maximum (689 – 862 kPa)
Volume - should be 3-5 CFM
Air Delivery system -
¼” minimum diameter airline with a ¼” N.P.T. connection.
Filtration
– Follow typical filtration requirements of air operated equipment. Standard filtering
systems should be located no further than 30
’ from this tool in addition to the
supplemental system supplied at the back of the tool as shown below. This BAND-IT
supplied system includes a filter and lubricator. Lubricator should be refilled with DTE
24 hydraulic oil. The oil drip-rate can be verified by repeated full cycling the tool. One
drop should fall in the sight glass within 10-25 cycles. Excess oil will not benefit tool life
and may lead to blockage of air mufflers and a dirty environment.
View of the back side of the S75099 showing the
supplemental filtering and lubrication system as well as
the
¼” N.P.T. air connection with typical quick connect
coupling.
Air System
Requirements
Serial #
decal
location
Warning:
The lubricator should be refilled with DTE 24 hydraulic