Acoustic Signalling and Keypad Configuration

3.1

46

Figure 3.6 Switching to Default Network Parameters – DHCP (Part Nos. 9137110E, 9137110CE,

9137110CKE, 9137111E, 9137111CE, 9137111CKE)

For one-button 2N

®

Helios IP modules (Part Nos. 9137110E, 9137110CE,

9137110CKE, 9137111E, 9137111CE, 9137111CKE), pushing key 1 fifteen times
within 30 seconds after the internal application launch as signalled by the

tone

sequence results in turning on of the web server and switching the network
parameters from the default static IP address to the dynamic address and vice versa.

Web Server Switch On

If the web server is switched off, switch it on using the quick dialling buttons of the
2N

®

Helios IP basic module as described in Figures 3.7–3.9. The buttons have to be

entered within 30 seconds after the internal application launch as signalled by the

tone sequence. The maximum delay between the buttons is 2 s.

Figure 3.7 Switching on Web Server Using Quick Dialling Buttons (Part Nos. 9137130E, 9137130CE,

9137130CKE, 9137131E, 9137131CE, 9137131CKE)