beautypg.com

2 table of parameters, Telephone line parameters – 2N Analogue GSM gateway 2N EasyGate - Manual, 1575 v1.1.0.2 User Manual

Page 29

background image

Table of Parameters

3.2

29

3.2 Table

of

Parameters

All programmable parameters are listed in this section. Each parameter is
accompanied with the unit used, function number (if available) for programming via a

telephone line, description of EasyGate's behavior, setting options, setting step and
default (initialization) value.

Telephone Line Parameters

Dialing parameters

Type

of

dialing

Function

No.:

-

Select the dialing type to be received by EasyGate from the PBX or telephone set.

EasyGate accepts only the selected type of dialing, ignoring the others.

Setting options:

DTMF -EasyGate receives tone dialing only.

Pulse

-EasyGate receives pulse dialing only

Default setting:

DTMF

Time

to

dial

[s]

Function

No.:

-

Timeout during which EasyGate waits for further digits to be dialed. It starts to

establish connection when this timeout passes.

Setting options:

1-15 s

Setting step:

1 s

Default setting:

5 s

Minimal

On

Hook

[ms]

Function

No.:

-

The minimum line current discontinuation that EasyGate evaluates as hang-up.

Setting options:

100-1500 ms

Setting step:

100 ms

Default setting:

500 ms

Beep after dialing end

Function No.: -

Select a beep to signal the end of dialing (beginning of outgoing call establishing).

Setting options:

YES/NO

Default setting:

YES