2N® EasyGate parameters configuration

3.1

25

To cancel any programming step in the programming mode, press a

. Having done

so, you can hear the refusal tone and can enter a new parameter number. Parameters

are saved when the saving tone is transmitted. Hang up to quit programming.
Example:

Dial 

Confirmation 

Description 

 

 

Password entering, OK 

 

 

Transmission volume parameter, OK 

 

 

Set to medium level, saved 

 

 

Non‐existent parameter number, refusal 

PC based Programming

For programming, connect EasyGate to a PC with a serial cable and make sure that

the EasyGate PCManager is installed. Programming is intuitive and easy. All steps are
accompanied with texts hints above all items you point at with the mouse.
EasyGate data uploading and storing, including firmware upgrade, are executed in a

special mode, in which EasyGate waits for about 3s after power up (all LEDs are on).
If instructed so by the PCManager during this timeout, EasyGate remains in this mode

as long as it is necessary. If EasyGate is not reset after the PCManager is terminated,
switch the system off and on again.

Language

selection

Data handling

Programming

tables

Monitoring

Figure 3.1

EasyGate

PC Manager

basic screen