See table 6-38 – JLG DVSP Series Service Manual User Manual
Page 144

SECTION 6 - TROUBLESHOOTING
6-30
– JLG Lift –
3121136
Codes (200 - 299) Platform Control Console - Fault Condition
Check For These Obvious Conditions First:
• Damage to Platform Control Console wiring harness.
• Secure harness connections from Platform Control Console to Platform Junction Box to Ground Control Module.
• Confirm that the static ground strap attached under base frame is secure and undamaged.
Table 6-38. Code (200 - 299) Platform Control Console - Fault Condition
STEP
ACTION
SPEC
YES
NO
1.
Recycle machine power 5 times allowing a 10 second interval
between each power recycle. Does fault clear?
—
Done
Go to Step 2
2.
Which 200 code number is displaying?
Code - 200/207/213
Go to Step 3
Replace
Platform
Control Module
Code - 202/205/206
Go to Step 4
3.
Remove the 9 pin Platform Control Module connector from the
side of the Platform Junction Box and the P4 connector at the
Ground Control Module. Check continuity from the P4 connector,
pin-5 to Junction Box pin-3 and P4, pin-9 to Junction Box pin-4.
Is there continuity on these wires?
—
Replace
Platform
Control Module
Repair or
Replace Wiring
4.
Perform the Joystick Calibration Procedure in Section 4.5 of this
Service Manual. Does this clear the fault code?
—
Done
Replace
Platform
Control Module