SECTION 5 - JLG CONTROL SYSTEM
5-4
– JLG Lift–
3121249
Adjusting Parameters Using the Hand Held
Analyzer
Once you have gained access to level 1, and a personality
item is selected, press the UP or DOWN arrow keys to
adjust its value, for example:
PERSONALITIES:
DRIVE ACCEL 3.0s
There will be a minimum and maximum for the value to
ensure efficient operation. The value will not increase if the
UP arrow is pressed when at the maximum value nor will
the value decrease if the DOWN arrow is pressed and the
value is at the minimum value for any particular personal-
ity. If the value does not change when pressing the up and
down arrows, check the access level to ensure you are at
access level 1.
Machine Setup
When a machine digit item is selected, press the UP or
DOWN arrow keys to adjust its value, for example:
FAILURE TO MAKE THE PROPER SETTINGS FOR THE PARTICU-
LAR MACHINE CAN RESULT IN IMPROPER OPERATION.
GROUND ALARM:
1=DESCENT
The effect of the machine digit value is displayed along
with its value. The above display would be selected if the
machine was equipped with a ground alarm and you
wanted it to sound when driving. There are certain set-
tings allowed to install optional features or select the
machine model.
When selecting the machine model to match the size of
the machine, the personality settings will return to default
settings.
PERSONALITIES:
DRIVE ACCEL 3.0s
GROUND ALARM:
1=DESCENT