Battery temperature sensor, Battery algorithms -11 – JLG M4069 ANSI Service Manual User Manual
Page 39
SECTION 3 - CHASSIS & SCISSOR ARMS
3121122
– JLG Lift –
3-11
Checking - Changing the Battery Charger Algo-
rithm
The charger is pre-loaded with programming algorithms
for the specific batteries detailed in Table 3-4, Battery
Algorithms on Page 3-11. Contact JLG if your specific bat-
tery model is not listed.
Each time AC power is applied with the battery pack not
connected, the charger enters an algorithm select/display
mode for approximately 11 seconds. During this time, the
current Algorithm # is indicated on the Yellow Charging
LED. A single digit Algorithm # is indicated by the number
of blinks separated by a pause. A two digit Algorithm # is
indicated by the number of blinks for the first digit followed
by a short pause, then the number of blinks for the second
digit followed by a longer pause.
To check / change the charging algorithm:
1. Disconnect the charger positive connector from the
battery pack. Apply AC power and after the LED test,
the Algorithm # will display for 11 seconds.
2. To change the algorithm, touch the connector to the
battery’s positive terminal for 3 seconds during the
11 second display period and then remove. The
Algorithm # will advance after 3 seconds. Repeat
this procedure until the desired Algorithm # is dis-
played. A 30 second time-out is extended for every
increment. Incrementing beyond the last Algorithm
will recycle back to the first Algorithm. When the
desired Algorithm is displayed, touch the charger
connector to the battery positive terminal until the
output relay makes a clicking noise (approx. 10 sec-
onds). The algorithm is now in the permanent mem-
ory.
3. Remove the AC power from the charger and recon-
nect the charger’s positive connector to the battery.
NOTE: It is recommended to check a newly changed algo-
rithm by repeating the above steps 1 and 3.
Battery Temperature Sensor
Machines equipped with the Delta-Q battery charger
include a battery temperature sensor. The sensor is
mounted to the negative terminal post of the inboard, front
battery on the machine’s left side mounted battery pack.
(See Figure 3-8.) The sensor is wired directly to the battery
charger.
Table 3-4. Battery Algorithms
Algorithm #
Battery Type
143
DISCOVER EVL1GA-A
43
Harris Battery - Discover EVGGC6A-A
Discover EV 305A-A
35
JLG P/N 0400242
23
Douglas Flooded (JLG default)
GES Battery A1055
Trojan T105
East Penn GC-110-WNL
Trojan T105 PLUS
Champion CHGC2 GC2
US BATT EV-145-WNL
US BATT 2200 XC
8
Concorde 10xAh AGM
7
J305 DV/DT CP
6
DEKA 8G31 Gel
5
Trojan 30/31XHS
4
US Battery USB2200
3
T105 DV/DT CP
2
Trojan T105 tapped
1
Trojan T105