3121122
Table 5-8. J4 Connector
PIN
TAGNAME
FUNCTION
TYPE
1
12V
12V Sensor Supply
POWER
OUTPUT
2
TILTX
X-Axis Tilt Input (PWM)
ANALOG
INPUT
3
TILTY
Y-Axis Tilt Input (PWM)
ANALOG
INPUT
4
GND
Ground
POWER
OUTPUT
Table 5-9. J5 Connector
PIN
TAGNAME
FUNCTION
TYPE
1
B+
Master Supply Connection (from J2-1)
POWER
OUTPUT
2
GNDE
Ground EMS (to J1-20, J3-22)
POWER
INPUT
3
PLTS
Platform Select Input (to J1-1)
POWER
INPUT
4
GNDS
Ground Select Input
POWER
INPUT
5
IGN
Ignition Power (+12V)
POWER
OUTPUT
6
GND
Ground
POWER
OUTPUT
7
UPG
Ground Lift Up Switch
DIGITAL
INPUT
8
DNG
Ground Lift Down Switch
DIGITAL
INPUT
9
FDH
Full Drive Height Input
DIGITAL
INPUT
10
DI19
High-Sensing Digital Input 19
DIGITAL
INPUT
11
DI20
High-Sensing Digital Input 20
DIGITAL
INPUT
12
DI21
High-Sensing Digital Input 21
DIGITAL
INPUT
13
GMST
Generator Manual Start (to J3-19)
POWER
I/O
14
GFLT
Generator Fault LED (to J3-21)
POWER
I/O
15
HRMT
Hourmeter
DIGITAL
OUTPUT
Table 5-10. J6 Connector
PIN
TAGNAME
FUNCTION
TYPE
1
12V
Ignition Power (+12V)
POWER
OUTPUT
2
RX
RS-232 Serial Receive
SERIAL
INPUT
3
TX
RS-232 Serial Transmit
SERIAL
OUTPUT
4
GND
Ground
POWER
OUTPUT