4 ground control circuit board, Software version 13.6, Ground control circuit board -19 – JLG M4069 ANSI Service Manual User Manual
Page 115: J1 connector -19
SECTION 5 - JLG CONTROL SYSTEM
3121122
– JLG Lift –
5-19
5.4 GROUND CONTROL CIRCUIT BOARD
Software Version 13.6
Table 5-5. J1 Connector
PIN
TAGNAME
FUNCTION
TYPE
1
PLTS
Platform Select
POWER
OUTPUT
2
PLTE
Platform EMS
POWER
INPUT
3
GND
Ground
POWER
OUTPUT
4
COL0
Column 0 Output
DIGITAL
OUTPUT
5
COL1
Column 1 Output
DIGITAL
OUTPUT
6
COL2
Column 2 Output
DIGITAL
OUTPUT
7
PCTL
Joystick Input (0 - 5VDC)
ANALOG
INPUT
8
ROW0
Row 0 Input
DIGITAL
INPUT
9
ROW1
Row 1 Input
DIGITAL
INPUT
10
COL3
Column 3 Output
DIGITAL
OUTPUT
11
COL4
Column 4 Output
DIGITAL
OUTPUT
12
COL5
Column 5 Output
DIGITAL
OUTPUT
13
ROW2
Row 2 Input
DIGITAL
INPUT
14
LCLK
LED Latch Clock Output
DIGITAL
OUTPUT
15
ALRM
Platform Alarm
DIGITAL
OUTPUT
16
IGN
Ignition Power (+12V; 750mA Limit)
POWER
OUTPUT
17
GALR
Ground Alarm
DIGITAL
OUTPUT
18
DO9
Spare High-Side Digital Output 9 (12V, 5A)
DIGITAL
OUTPUT
19
QPRX
Trigger Switch
POWER
INPUT
20
GNDE
Ground EMS (from J5-2; 500mA Limit)
POWER
OUTPUT
21
GINH
Generator Inhibit Start Switch
POWER
I/O
22
GND
Ground
POWER
OUTPUT
23
GND
Ground
POWER
OUTPUT
24
GND
Ground
POWER
OUTPUT