Table 5-2. Power Module Diagnostic LED Flash Codes
Flash Code
Fault
Constant Illumination
No Fault, Normal Condition
LED Extinguished
Internal Controller Fault
1 Flash
Personality Out of Range
2 Flashes
Illegal Start Condition or Illegal Steer Switch Input
3 Flashes
MOSFET Short Circuit
4 Flashes
Contactor Fault or Motor Open Circuit
5 Flashes
Not Used
6 Flashes
Accelerator, Steer Pot or Speed Probe Wire Default
7 Flashes
Low or High Battery Voltage or BDI Cut-Out Operating
8 Flashes
Over Temperature
9 Flashes
Contactor Coil Short Circuit
12 Flashes
CAN Bus Fault