beautypg.com

Operation manual, System overview – Class1 118253 - ITL40 108404-XX - Full User Manual

Page 5

background image

FORM-ENG-0018 REV A 05-27-03

PAGE

4 of 25

S U I T A B L E F O R E X T E R N A L D I S T R I B U T I O N

OPERATION MANUAL

DATE

9/24/2008

PRODUCT GROUP

ITL40

P/N

118404-XX

REV

1.00

607 NW 27th Ave

Ocala, FL 34475

Ph: 352-629-5020 or 1-800-533-3569

Fax : 352-629-2902 or 1-800-520-3473

PRODUCT

Intelli-Tank Level 40

BY

AMS

MANUAL

P/N:118253

P

RINTED

:

1/8/09


2. System

Overview

2.1. Scope

The Intelli-Tank Level 40 (ITL40) is designed to display a liquid’s volume to an eighth of a tank level accuracy through
180-degree viewable ultra-bright LEDs. An Intelli-Tank Level 40 set as a MASTER uses a 0-5 PSI (0-34.47 kPa,
0-0.3447 bar) pressure sensor to obtain tank level information and then relays that information along the
communication line(s) (1-Wire or CAN) to ITL40’s set as REMOTES. Multiple REMOTE units can be linked to the
MASTER tank level.

2.2. Part

numbers

Tank Level Gauge

C1 – p/n 118404-01 – Red LEDs

p/n

118404-02

Amber LEDs

p/n 118404-03 – Yellow LEDs

p/n

118404-04

Green LEDs

p/n

118404-05

Blue LEDs

p/n 118404-06 – 2 Red, 2 Yellow, 2 Blue, 2 Green rows of LEDs


Labels

C1 – p/n 117691

– water (blue)

p/n 117692

– foam (red)

p/n 117693

– foam (green)

Pressure Sensor

C1 – p/n 102162

– 0 to 5 PSI (0 to 34.47 kPa, 0 to 0.3447 bar) gage


Adapter bushing

C1 – p/n 102219

– ¾ to ¼ NPT


Installation Harness

C1 – p/n 118485-10 – Master display, 10 feet

p/n

118485-20

Master display, 20 feet

p/n

118485-30

Master display, 30 feet

p/n

118485-40

Master display, 40 feet

p/n 118695

– Remote display


Terminating resistor (CAN) C1 – p/n DT06-3S-P006

“Y” connector (CAN)

C1 – p/n DT04-3P-P007


Operation Manual

C1 – p/n 118253


One Page Manual

C1 – p/n 118252


2.3. Modes of Operation

Master

When the ITL40 display is calibrated with a proper pressure signal it automatically becomes a MASTER
display and will send tank level information along the communication line(s) (either 1-wire or CAN) to all
other REMOTE displays.


Remote

ITL40 displays are initially shipped as REMOTE displays. A REMOTE display only requires power,

ground and communications line(s) (either 1-wire or CAN). The REMOTE display mimics the MASTER
display’s LEDs by reading the appropriate information on the communication line(s).