2. System
Overview
2.1. Scope
The Intelli-Tank Level 40 (ITL40) is designed to display a liquid’s volume to an eighth of a tank level accuracy through
180-degree viewable ultra-bright LEDs. An Intelli-Tank Level 40 set as a MASTER uses a 0-5 PSI (0-34.47 kPa,
0-0.3447 bar) pressure sensor to obtain tank level information and then relays that information along the
communication line(s) (1-Wire or CAN) to ITL40’s set as REMOTES. Multiple REMOTE units can be linked to the
MASTER tank level.
2.2. Part
numbers
Tank Level Gauge
C1 – p/n 118404-01 – Red LEDs
p/n
118404-02
–
Amber LEDs
p/n 118404-03 – Yellow LEDs
p/n
118404-04
–
Green LEDs
p/n
118404-05
–
Blue LEDs
p/n 118404-06 – 2 Red, 2 Yellow, 2 Blue, 2 Green rows of LEDs
Labels
C1 – p/n 117691
– water (blue)
p/n 117692
– foam (red)
p/n 117693
– foam (green)
Pressure Sensor
C1 – p/n 102162
– 0 to 5 PSI (0 to 34.47 kPa, 0 to 0.3447 bar) gage
Adapter bushing
C1 – p/n 102219
– ¾ to ¼ NPT
Installation Harness
C1 – p/n 118485-10 – Master display, 10 feet
p/n
118485-20
–
Master display, 20 feet
p/n
118485-30
–
Master display, 30 feet
p/n
118485-40
–
Master display, 40 feet
p/n 118695
– Remote display
Terminating resistor (CAN) C1 – p/n DT06-3S-P006
“Y” connector (CAN)
C1 – p/n DT04-3P-P007
Operation Manual
C1 – p/n 118253
One Page Manual
C1 – p/n 118252
2.3. Modes of Operation
Master
When the ITL40 display is calibrated with a proper pressure signal it automatically becomes a MASTER
display and will send tank level information along the communication line(s) (either 1-wire or CAN) to all
other REMOTE displays.
Remote
ITL40 displays are initially shipped as REMOTE displays. A REMOTE display only requires power,
ground and communications line(s) (either 1-wire or CAN). The REMOTE display mimics the MASTER