Operation manual, Communication wiring examples – Class1 118253 - ITL40 108404-XX - Full User Manual
Page 19
FORM-ENG-0018 REV A 05-27-03
PAGE
18 of 25
S U I T A B L E F O R E X T E R N A L D I S T R I B U T I O N
OPERATION MANUAL
DATE
9/24/2008
PRODUCT GROUP
ITL40
P/N
118404-XX
REV
1.00
607 NW 27th Ave
Ocala, FL 34475
Ph: 352-629-5020 or 1-800-533-3569
Fax : 352-629-2902 or 1-800-520-3473
PRODUCT
Intelli-Tank Level 40
BY
AMS
MANUAL
P/N:118253
P
RINTED
:
1/8/09
6.3. Communication wiring examples
The ITL40 display can be set up to use the 1-wire or CAN communication methods. The simplest system would be
comprised of a single ITL40 MASTER display.
6.3.1.
1-wire method, 1 MASTER and 2 REMOTES
System configured with 1-wire communication method. Make certain that the ground for each display is tied to a
common point or the REMOTE displays will not receive communication data from the MASTER display.
6.3.2.
1-wire method, 2 MASTERS and 2 REMOTES
System configured with 1-wire communication method. Make certain that the two MASTER 1-wire data lines are
not connected and that the ground for each display is tied to a common point or the REMOTE displays will not
receive communication data from their associated MASTER display.