FORM-ENG-0018 REV A 05-27-03

PAGE

20 of 25

S U I T A B L E F O R E X T E R N A L D I S T R I B U T I O N

OPERATION MANUAL

DATE

9/24/2008

PRODUCT GROUP

ITL40

P/N

118404-XX

REV

1.00

607 NW 27th Ave

Ocala, FL 34475

Ph: 352-629-5020 or 1-800-533-3569

Fax : 352-629-2902 or 1-800-520-3473

PRODUCT

Intelli-Tank Level 40

BY

AMS

MANUAL

P/N:118253

P

RINTED

:

1/8/09

6.3.5.

Terminating resistor requirement (CAN communication)

Two terminating resistors (120 Ohm) are required on the CAN bus for proper operation (one at each end of the
CAN bus). Only two terminating resistors are allowed on a CAN bus.


Terminating resistor

p/n DT06-3S-P006


CAN 3-way “Y” connector p/n DT04-3P-P007

6.4. Communication compatibility with Class 1 products

The ITL40 display is compatible with other Class 1 CAN and 1-wire products.

6.4.1. 1-wire

compatibility

An ITL40 display configured with 1-wire communication is compatible with…

4 light remote driver module (p/n 106877)

Pump input sensor module (p/n 111097)

Mini remote driver module (p/n 112648)

Mini remote dash gauge (p/n 112649)

4 and 5 light ITL displays (p/n 106299, 106296, 108858, 108859, 113739, 114378, 114005, 114379)

6.4.2. CAN

compatibility

An ITL40 display configured with CAN communications is compatible with…

Command Master (p/n 111084, 111085, 111086)

Pump input sensor module (p/n 111097)

4 and 5 light ITL displays (p/n 113739, 114378, 114005, 114379)