beautypg.com

Operation manual – Class1 118253 - ITL40 108404-XX - Full User Manual

Page 23

background image

FORM-ENG-0018 REV A 05-27-03

PAGE

22 of 25

S U I T A B L E F O R E X T E R N A L D I S T R I B U T I O N

OPERATION MANUAL

DATE

9/24/2008

PRODUCT GROUP

ITL40

P/N

118404-XX

REV

1.00

607 NW 27th Ave

Ocala, FL 34475

Ph: 352-629-5020 or 1-800-533-3569

Fax : 352-629-2902 or 1-800-520-3473

PRODUCT

Intelli-Tank Level 40

BY

AMS

MANUAL

P/N:118253

P

RINTED

:

1/8/09

Condition

Visual

Evaluate

No passwords are

accepted.

If the display flashes “X” four times after entering a password, insure the display is
installed right side up. During power-up the display should turn on all LEDs and

then cycle them OFF starting with the top row, then the display should scroll the

custom greeting from right to left.

Check that the left and right magnetic switches are recognized by activating each
switch and verifying that the associated LEDs illuminate.

The bottom four LED

rows are on and

occasionally they go out

and the top four LED

rows flash and then

return to the bottom four

LED rows on (or vice-

versa). (REMOTE).

Check for large noise spikes on the 1-wire data line.

Insure that the display’s ground potential is the same as the MASTER’s.

Insure that the data line is not chaffed and making contact with other electrical

wires.

The points calibrated

seemed to have

changed.

No picture

Check the pressure sensor for problems.

Recalibrate the display and take a voltage reading from the sensor (pin 6 on the

display’s connector) at each calibration point. When the calibration points again

look wrong check the voltages at those points and determine if they are the same
as the voltage reading taken during calibration – if they are not then replace the

sensor.

Unit will not dim display.

No picture

Insure the Dim input voltage on Pin 4 is at least 9V. Recalibrate dim setting

(RLLR LLLR). If display does not dim LEDs while in the dim configure mode,

replace display.

The middle two LED

rows are flashing

together.

A calibration was started on the display but not completed correctly. Set the

display to a REMOTE display (LRLR LRLR) or calibrate it as a MASTER (follow

calibration steps exactly).

LEDs cycle ON toward

the center continuously.

The display has had a unit type memory error.

Attempt to set the display back to REMOTE or MASTER as required.

Replace the display if this error cannot be corrected.


7.2. Using the display to verify pressure sensor signal voltage

The display can show the voltage level that it detects on the pressure sensor signal line by entering the password
LLRR LLRR

.

The display will then scroll the text “VOLTS” and then continue to scroll the voltage detected at pin 6.

The display will continue showing the voltage until either of the magnetic switches is activated.