1/8/09

9. Technical

details

9.1. Technical

details

Product category

ITL40 (Intelli-Tank Level 40)

Voltage range

+9VDC…+32VDC

Power consumption
@13.8VDC (25ºC)
@27.6VDC (25ºC)


100 mA
52 mA

Operational temperature range

-40ºC…+85ºC

Environmental range

IP 67

CAN specification

SAE J1939 proprietary, 250 Kbits/second

1-Wire specification

Class 1 proprietary, 425 bits/second

Protection

Internal thermal fuse
Reverse voltage protection (pins 1 and 12 of connector)
CAN buses protected to 24V
ESD voltage protected to SAE J1113 specification for heavy duty trucks
Transient voltage protected to SAE J1113 specification for heavy duty trucks

Dimensions (W x H x D) in inches [mm]

3.185 [80.90] x 5.125 [130.17] x 2.150 [54.61]

Weight in ounces [grams]

7.9 [223.96]



9.2. WEEE (Waste of Electrical and Electronic Equipment) directive

This symbol [crossed-out wheeled bin WEEE Annex IV] indicates separate collection of waste electrical and
electronic equipment in the European Union countries.
Please do not throw the equipment into the domestic refuse.
Each individual European Union member state has implemented the WEEE regulations into national law in
slightly different ways. Please follow your national law when you want to dispose of any electrical or electronic
products.

More details can be obtained from your national WEEE recycling agency.


9.3. CE

statement

This device complies with the European Regulations for Electromagnetic Compatibility (EMC) of the European
Union and it is equipped with the CE mark. This unit must be used in accordance with the details specified within
this manual.