beautypg.com

Operation manual – Class1 118253 - ITL40 108404-XX - Full User Manual

Page 13

background image

FORM-ENG-0018 REV A 05-27-03

PAGE

12 of 25

S U I T A B L E F O R E X T E R N A L D I S T R I B U T I O N

OPERATION MANUAL

DATE

9/24/2008

PRODUCT GROUP

ITL40

P/N

118404-XX

REV

1.00

607 NW 27th Ave

Ocala, FL 34475

Ph: 352-629-5020 or 1-800-533-3569

Fax : 352-629-2902 or 1-800-520-3473

PRODUCT

Intelli-Tank Level 40

BY

AMS

MANUAL

P/N:118253

P

RINTED

:

1/8/09

LRRR RLLL

address 4). All REMOTE displays that are to mimic the MASTER display must have their addresses

matching the MASTER’s.
The display can also be configured to mimic a Class 1 Pump Sensor Module (p/n 111097) by entering the
password for the desired tank (LRRR LRLL PCM tank 1, LRRR RLRL PCM tank 2, LRRR RLRR PCM tank 3).

3.8. Configure a custom message scroll

The ITL40 scrolls a custom message during start-up. The default scroll text is “Class 1” but the text can be custom
configured to a desired message (maximum of 21 characters allowed).

List of available characters.

A B C D E F G H I J K L M N O P Q R S T U V

W X Y Z

SP

0 1 2 3 4 5 6 7 8 9 + - / = ? .


Enter the password LLLL LRLR and the display will show the first available character - “A”.

Use the LEFT and RIGHT magnetic switches to enter the desired text.

The LEFT magnetic switch changes the character. Each LEFT switch activation moves forward or backward
through the available characters. Wait two seconds between switch activations and the direction reverses.

The RIGHT magnetic switch saves the displayed character to memory.

There are three methods of exiting…

Save two SPACE characters in a row.

Configure the maximum number of characters (21).

Turn OFF power to the ITL40.


The custom message scroll can also be configured through a CAN message. Contact Class 1 for details.

3.9. Use the display reference mark



The level the ITL40 shows may be difficult to distinguish at a distance for some
viewers. The ITL40 can be configured with a reference mark at the top of the
display (single LED ON) which will help quickly determine level.

Enter the password LLRR RRRR to turn the reference mark ON.

Enter the password LLRR LLLL to turn the reference mark OFF.

The default for the reference mark is OFF.