beautypg.com

Operation manual – Class1 118253 - ITL40 108404-XX - Full User Manual

Page 20

background image

FORM-ENG-0018 REV A 05-27-03

PAGE

19 of 25

S U I T A B L E F O R E X T E R N A L D I S T R I B U T I O N

OPERATION MANUAL

DATE

9/24/2008

PRODUCT GROUP

ITL40

P/N

118404-XX

REV

1.00

607 NW 27th Ave

Ocala, FL 34475

Ph: 352-629-5020 or 1-800-533-3569

Fax : 352-629-2902 or 1-800-520-3473

PRODUCT

Intelli-Tank Level 40

BY

AMS

MANUAL

P/N:118253

P

RINTED

:

1/8/09

6.3.3.

CAN method, 1 MASTER and 2 REMOTES

System configured with CAN communication method. This example shows one MASTER display (configured with
address 1) communicating with 2 REMOTE displays (configured with address 1).

Two CAN terminating resistors (p/n DT06-3S-P006) are required in the system (one at each end of the CAN bus).

6.3.4.

CAN method, 2 MASTERS and 2 REMOTES

System configured with CAN communication method. This example shows two MASTER displays (configured
with address 1 and address 2) communicating with 2 REMOTE displays (configured with address 1 and address 2).
REMOTE display address 1 only follows the indications of MASTER display address 1, and REMOTE display
address 2 only follows the indications of MASTER display address 2.

Two CAN terminating resistors (p/n DT06-3S-P006) are required in the system (one at each end of the CAN bus).