beautypg.com

Display, Interlock status indicators, Control switches – Class1 117155 - TPG Governor - 117684 EXTERNAL User Manual

Page 8: Idle, Menu/silence, Preset, Mode, Mode indicator, Technical data sheet

background image

FORM-ENG-0018 REV A 05-27-03

607 NW 27th Ave

Ocala, FL 34475

Ph: 352-629-5020 or 1-800-533-3569

Fax : 352-629-2902 or 1-800-520-3473

TECHNICAL DATA SHEET

PAGE

7

OF 26

DATE

3/28/2012

PRODUCT GROUP

THROTTLE CONTROL

P/N

117155

REV

1.23

PRODUCT

TOTAL PRESSURE GOVERNOR (TPG)

BY

AMS


Manual P/N 117684

3.1. Display

The display shows the pertinent governor information: engine RPM, set pressure, warning and information messages.

3.2. Interlock status indicators

Backlit text indicates the status of the three (3) interlocks: pump engaged, okay to pump, and throttle ready. Throttle
ready
and pump engaged are physical inputs into the TPG’s 12 pin connector (pins 2 and 10 respectively). Okay to
pump
interlock status can be configured to become active when both the throttle ready and pump engaged interlocks
are present (default) or when the TPG’s pin 4 physical input is active (see section 5.2.34).

3.3. Control switches

The six (6) control switches are color coded and labeled for easy identification.

3.3.1.

IDLE

The IDLE switch (red) forces the governor to idle mode (standby). Pressing and holding this button for one second

while in rpm or pressure mode will cause the engine to ramp down to its idle position.

3.3.2.

MENU/SILENCE

The MENU/SILENCE switch (blue) is used to silence the alarm, cycle through the display items, and enter the
setup menu.

3.3.3.

PRESET

The PRESET switch (orange) sets the governor to the configured preset engine RPM while in throttle mode, or
preset pressure while in pressure mode.

3.3.4.

MODE

The MODE switch (green) sets the governor to either throttle mode (RPM) or pressure mode (PSI). The correct

interlocks must be present for the system to begin governor operation: throttle ready for RPM mode, throttle ready,
pump engaged, and okay to pump for PSI mode.

3.3.5.

INC

The INC [increase] switch (yellow) is used to increase the engine RPM or pressure set point.

3.3.6.

DEC

The DEC [decrease] switch (yellow) is used to decrease the engine RPM or pressure set point.

3.4. Mode indicator

The mode indicator consists of two (2) LEDs to show the governor’s current operating mode. The PSI LED (yellow)
indicates the governor is operating in pressure mode and the RPM LED (blue) indicates the governor is operating in
throttle mode. When both LEDs are OFF the governor is in idle mode (standby).