Module operating parameters, Technical data sheet – Class1 117155 - TPG Governor - 117684 EXTERNAL User Manual
Page 30
FORM-ENG-0018 REV A 05-27-03
607 NW 27th Ave
Ocala, FL 34475
Ph: 352-629-5020 or 1-800-533-3569
Fax : 352-629-2902 or 1-800-520-3473
TECHNICAL DATA SHEET
PAGE
29
OF 26
DATE
3/28/2012
PRODUCT GROUP
THROTTLE CONTROL
P/N
117155
REV
1.23
PRODUCT
TOTAL PRESSURE GOVERNOR (TPG)
BY
AMS
Manual P/N 117684
10. Module Operating Parameters
Product category
Throttle Control
Voltage range
+9VDC…+32VDC
Power consumption
@13.8VDC
@27.6VDC
Logic supply+ input (pin 1 of the 6-pin Deutsch connector)
350mA
195mA
Output power
Alarm
250mA (ground polarity)
Operational temperature range
-40ºC…+85ºC
Environmental range
IP 67
CAN specification
SAE CAN 2.0B J1939 , 250 Kbits/second (engine, transmission)
Protection
Internal thermal fuse (1850mA on pin 1 of the 6-pin Deutsch connector)
Reverse voltage protection (pins 1 and 2 of the 6-pin Deutsch connector)
CAN buses protected to 24V
ESD voltage protected to SAE J1113 specification for heavy duty trucks (24V)
Transient voltage protected to SAE J1113 specification for heavy duty trucks (24V)
Load dump voltage protected to SAE J1113 specification for heavy duty trucks (24V)
Outputs protected for short circuit and thermal overload
Dimensions (W x H x D) in inches [mm]
4.437 [112.70] x 6.000 [152.39] x 2.250 [57.15]