beautypg.com

Technical data sheet – Class1 117155 - TPG Governor - 117684 EXTERNAL User Manual

Page 15

background image

FORM-ENG-0018 REV A 05-27-03

607 NW 27th Ave

Ocala, FL 34475

Ph: 352-629-5020 or 1-800-533-3569

Fax : 352-629-2902 or 1-800-520-3473

TECHNICAL DATA SHEET

PAGE

14

OF 26

DATE

3/28/2012

PRODUCT GROUP

THROTTLE CONTROL

P/N

117155

REV

1.23

PRODUCT

TOTAL PRESSURE GOVERNOR (TPG)

BY

AMS


Manual P/N 117684

Menu items in menu levels 1, 2, and 3

MENU ITEM

DESCRIPTION

DEFAULT

MENU LEVEL

UNITS

Configures units of measure

PSI / ºF

1

PRESET RPM

Configures the throttle mode (RPM) preset (900 – 1400)

(Not available with message type ANLG)

1000

1*

HI-IDLE

Configures the high idle RPM preset (900-1400)

(Not available with message type ANLG)

1100

1*

PRESET PSI

Configures the pressure mode (PSI) preset (90 – 130)

90

1

BRIGHT

Configures the display’s brightness level (1-15)

15

1

DISPLAY TEST

Tests all of the pixels of the main display

N/A

1

ROUND PSI

Configures the rounding of the pressure value

N

1

ALERT TONE

Alert tones are indicated by a double chirp of the alarm output and
do not indicate alarm conditions. Enable/disable the alert tones.

Y

2

SENSITIVITY

Configures the pressure sensitivity window (4 – 12)

+/- 6 PSI

2

-SENSOR CAL-

Calibrates the zero point of the pressure sensor

142 COUNTS

2

1ST MODE

Configures the first mode active when the MODE switch is pressed
(interlocks permitting)

PSI

2

AUTO MODE

Configures if governor automatically enters into psi mode upon
pump engagement.

(Only available when 1

st

mode menu item is set to PSI and menu level was 3 or greater)

NO

3*

COMM STATUS

Allows viewing of CAN messages per second and received errors

N/A

2

CONTROL

Configure control mode and message for engine

CFPG (Cummins)

3

RPM IDLE

Configure / adjust the idle rpm

(Not available with message type ANLG)

700

3*

RPM MAX

Configure / adjust the maximum rpm commanded by governor

(Not available with message type ANLG or CFPG)

2200

3*

SOURCE ID

Configure the CAN source ID for the TPG

(only available with message type PGN0 or SCAN)

7

3*

TSC1 RAMP

Configure the RPM ramp speed of TSC1/PGN0 control mode

(only available with message type PGN0)

0

3*

DISPLAY

Configure primary display while in pressure mode (rpm or pressure)

RPM

3

PSI TIME-OUT

Configures the amount of seconds the TPG will wait after pressure
has dropped below 30 PSI before dropping to IDLE mode

5

3

ALLOW PRESET

Configure enable/disable rpm preset if pump is under pressure

NO

3

WARNINGS

Configures source of the panel warning LED’s (data bus or user
defined)

Bus

3

WARN

°

F

Configure the yellow (warning) engine temp setpoint

(only available when WARNINGS is set to Usr)

-

3*

CRIT

°

F

Configure the red (critical) engine temp setpoint

(only available when WARNINGS is set to Usr)

-

3*

WARN

PSI

Configure the yellow (warning) oil pressure setpoint

(only available when WARNINGS is set to Usr)

-

3*

CRIT PSI

Configure the red (critical) oil pressure setpoint

(only available when WARNINGS is set to Usr)

-

3*