Universal 8 39 – AEM Infinity Supported Applications - Universal V8 Engine User Manual
Page 39
![background image](/manuals/546711/39/background.png)
Universal 8
39
© 2014 AEM Performance Electronics
Infinity
Pin
Hardware Ref.
7100-XXXX-62
7101-XXXX-63
Function
Hardware Specification
Notes
C1-30
Power Ground
Ground
Power Ground
Connect directly to battery ground.
C1-31
CANL_Aout
AEMNet CANL
Dedicated High Speed CAN Transceiv er
Recommend twisted pair (one twist per 2")
with terminating resistor. Contact AEM f or
additional inf ormation.
C1-32
CANH_Aout
AEMNet CANH
Dedicated High Speed CAN Transceiv er
Recommend twisted pair (one twist per 2")
with terminating resistor. Contact AEM f or
additional inf ormation.
C1-33
LowsideSwitch_1
Boost Control
Lowside switch, 4A max with internal
f ly back diode. Inductiv e load should NOT
hav e f ull time power.
See Setup Wizard page Boost Control f or
options. Monitor BoostControl [%] channel
f or output state.
C1-34
LowsideSwitch_0
Fuel Pump
Lowside switch, 4A max, NO internal
f ly back diode.
Switched ground. Will prime f or 2 seconds
at key on and activ ate if RPM > 0.
C1-35
Analog_In_7
Throttle Position
Sensor
12 bit A/D, 100K pullup to 5V
0–5V analog signal. Use +5V Out pins as
power supply and Sensor Ground pins as
the low ref erence. Do not connect signals
ref erenced to +12V as this can
permanently damage the ECU. See the
Setup Wizard Set Throttle Range page f or
automatic min/max calibration.
C1-36
Analog_In_8
MAP Sensor
12 bit A/D, 100K pullup to 5V
0–5V analog signal. Use +5V Out pins as
power supply and Sensor Ground pins as
the low ref erence. Do not connect signals
ref erenced to +12V as this can
permanently damage the ECU. See the
Setup Wizard Set Manif old Pressure page
f or setup and calibration.
C1-37
Analog_In_9
Fuel Pressure
12 bit A/D, 100K pullup to 5V
0–5V analog signal. Use +5V Out pins as
power supply and Sensor Ground pins as
the low ref erence. Do not connect signals
ref erenced to +12V as this can
permanently damage the ECU. See the
Setup Wizard Fuel Pressure page f or
setup and calibration.
C1-38
Analog_In_10
Baro Sensor
12 bit A/D, 100K pullup to 5V
0–5V analog signal. Use +5V Out pins as
power supply and Sensor Ground pins as
the low ref erence. Do not connect signals
ref erenced to +12V as this can
permanently damage the ECU. See the
Setup Wizard Barometric Pressure page
f or setup and calibration.
C1-39
Analog_In_11
Spare Analog
Input
12 bit A/D, 100K pullup to 5V
0–5V analog signal. Use +5V Out pins as
power supply and Sensor Ground pins as
the low ref erence. Do not connect signals
ref erenced to +12V as this can
permanently damage the ECU. Normally
used as Shif t Switch input.
C1-40
Analog_In_12
Spare Analog
Input
12 bit A/D, 100K pullup to 5V
0–5V analog signal. Use +5V Out pins as
power supply and Sensor Ground pins as
the low ref erence. Do not connect signals
ref erenced to +12V as this can
permanently damage the ECU. Normally
used as Mode Switch input.
C1-41
+5V_Out_1
+5V Out
Regulated, f used +5V supply f or sensor
power
Analog sensor power