beautypg.com

Lowside assignment – generator control, Lowside assignment – reverse lock-out – AEM Infinity Supported Applications - Dodge 2008-2010 Viper 4G User Manual

Page 8

background image

8

© 2014 AEM Performance Electronics

LowSide Assignment – Generator Control

In the Lowside Assignment Tables tab, confirm the following settings:

Frequency

= 125 Hz

LS6_Duty X-Axis

= Engine Speed [RPM]

LS6_Duty Y-Axis

= Battery [Volts]

LowSide Assignment – Reverse Lock-Out

In the Lowside Assignment Tables tab, confirm the following settings:

Frequency

= 30 Hz

LS7_Duty X-Axis

= Vehicle Speed [MPH]

LS7_Duty Y-Axis

= Engine Speed [RPM]