To join the AEM network, connect the Deutsch male connector to the female connecter
of other AEM devices in the network (Figure 11).


FIGURE 11. AEMnet cable connection


Connecting To The AEMnet Network Using a non-AEM Device with CAN

Each AEMnet connector has 4 pins, CAN+ (PIN1, White), CAN- (PIN2, Green) and two
pins for power carry-over (PIN3 and PIN4, Red and Black). NOTE: Pin numbers are
located at the back of the connector. Non-AEM devices can connect to the AEMnet by
connecting their CAN +/- wires to the CAN+/- wires on the AEM network. The parts for
mating connectors are listed below and shown in Figure 12.

• Deutsch DTM04-4P (Receptacle connector)

• Deutsch 1060-20-0122 (Pins)

• Deutsch DTM06-4S (Plug connector)

• Deutsch 1062-20-0122 (Pins)

Figure 12. Connector Assembly