7 *opt, 8 *rcl Page 14: 10 *sav
Page 14: 10 *sav

Berkeley Nucleonics Corporation 2955 Kerner Blvd., San Rafael, CA 94901
Phone: 415-453-9955, Fax: 415-453-9956, Email: [email protected], Web: www.berkeleynucleonics.com
3.1.7
*OPT?
The options (OPT) query returns a comma-separated list of all currently installed instrument options on
the signal generator.
Returned option strings are:
0
Basic device
B3
Rechargeable battery pack
PE|PE2|PE3
Extended power range
AVIO
ILS and VOR modulations
GPIB
GPIB (IEEE 488) programming interface
3.1.8
*RCL
The Recall (RCL) command recalls the state from the specified memory register
3.1.9
*RST
The Reset (RST) command resets most signal generator functions to factory- defined conditions.
Remarks Each command shows the [*RST] default value if the setting is affected.
3.1.10 *SAV
The Save (SAV) command saves signal generator settings to the specified memory register
Remarks The save function does not save all signal generator settings. Refer to the User’s Guide for
more information on the save function.
3.1.11 *SRE
The Service Request Enable (SRE) command sets the value of the Service Request Enable Register.
The variable is the decimal sum of the bits that will be enabled. Bit 6 (value 64) is ignored and
cannot be set by this command.
Range 0–255
The setting enabled by this command is not affected by signal generator preset or
*RST. However, cycling the signal generator power will reset it to zero.
3.1.12 *SRE?
The Service Request Enable (SRE) query returns the value of the Service Request Enable Register.
Range 0–63 & 128-191