beautypg.com

4 use of the capacity chart, Capacity indicator locations, 4 use of the capacity chart -4 – JLG G6-42P Service Manual User Manual

Page 66: Capacity indicator locations -4

background image

Section 5 - Attachments

5-4

31200148

5.4

USE OF THE CAPACITY CHART

To properly use the capacity chart (see page 5-5), the operator must first determine
and/or have the following:

1. A JLG approved attachment. See “Approved Attachments” on page 5-1.

2. The proper Capacity Chart(s).

3. Weight of the load being lifted.

4. Load placement information:

a. HEIGHT where the load is to be placed.

b. DISTANCE from the front tires of the telehandler where the load is to be

placed.

5. On the Capacity Chart, find the line for the height and follow it over to the

distance.

6. The number in the load zone where the two cross is the maximum capacity for

this lift. If the two cross at a division between zones, the smaller number must
be used.

The number in the load zone must be equal to or greater than the weight of the load
to be lifted. Determine the limits of the load zone on the Capacity Chart and keep
within these limits.

Capacity Indicator Locations

OX0190

-10°

10°

20°

30°

40

°

50

°

60

°

70

°

80

°

Boom Extension

Indicator

Fork

Weight

Stamp

Attachment

Identification

Plate

Boom
Angle

Indicator