Vi general maintenance, Vii general maintenance – Fluid Management 22CW Blendorama User Manual
Page 22

FAST & FLUID MANAGEMENT
PAGE NO. 22 of 27
CW - V1.2 – 10- 05- 2012 (36609) – rev, B
VI
GENERAL MAINTENANCE
VII
GENERAL MAINTENANCE
Step 3
Returning plungers into cylinders
>
>
(1) After lightly oiling the top
inside edge of the cylinder,
position the plunger assembly
on the cylinder with one hand.
With the palm of the other
hand, firmly push the plunger
down fully.
(2) Tighten end cap assembly
onto cylinder assembly using
Allen key.
(3) Remove the sleeve from
the inner piston and discard.
Lightly oil the inside edge of
the hollow outer piston shaft
and then gently ease the
piston inside. Refit the
gauges.