Figure 6a-7: limit switch / cam adjustment, Important – Hale Torrent SVS Stainless Steel Valves User Manual
Page 41
![background image](/manuals/545166/41/background.png)
41
Torrent SVS Installation / Service Manual
p/n: 029-0020-90-0
Corrective Maintenance
❑
Figure 6a-7: Limit Switch / Cam Adjustment
1. Remove the actuator lid and note the location of the wire grommet.
IMPORTANT !
DO NOT REMOVE THE GREASE THAT IS AROUND THE SEALING AREA OF THE
LID.
2. Standard actuators rotate from the OFF position, counterclockwise 90° (when
viewed from top of unit) to the ON position, then rotate 90° clockwise back to
the OFF position.
3. For “fine” adjustments, the limit switch actuator arms can be bent slightly to
fine tune the ON and OFF points. (See Figure 6a-7: “Limit Switch / Cam
Adjustment.”)