Electric actuator option, Valve does not fully open or close, Motor does not run – Hale Torrent SVS Stainless Steel Valves User Manual
Page 40: Constantly tripping integrated circuit breaker, Valve is leaking past the ball, Mastergear valve actuators, Electric valve actuator - eh2 / eh4, Limit switch / cam adjustment
❑ Corrective Maintenance
40
Torrent SVS Installation / Service Manual
p/n: 029-0020-90-0
Electric Valve Actuator - EH2 / EH4
Limit Switch / Cam Adjustment
Standard electric actuators, shipped separately (without valves), may require
field limit switch / cam adjustment. If done properly, this field adjustment will not
void the warranty. (See Figure 6a-7: “Limit Switch / Cam Adjustment,” on page
41.)
Electric Actuator Option:
Valve does not fully OPEN or
CLOSE.
Motor does not run -
Due to limit switch setting or
defective wire harness.
Constantly tripping integrated
circuit breaker.
Valve is leaking past the ball -
Suspect valve not stopping at
proper CLOSED position.
• If the electric actuator is suspect, remove it and operate the valve. If the valve oper-
ates normally, repair or replace the electric actuator.
• If the electric actuator operates normally when removed from the valve, remove and
dismantle the valve as necessary. See Section 6, heading “6.3 Servicing the Valve,”
on page 27.
• Limit switches set incorrectly or defective. See heading “Limit Switch / Cam Adjust-
• Damaged or broken wire harness - repair and/or replace accordingly.
• Disconnect power to the unit for twenty (20) seconds, then reconnect power.
• Defective or damaged relay inside the motor case. Listen for audible “clink” upon acti-
vation. If not, replace the relay PC Board.
• Valve ball too tight. Inspect the valve ball and valve seals for foreign debris, deteriora-
tion, or damage that could cause interference between the valve ball and the seals or
valve body, hindering proper operation.
• Failure to correct condition will render motor defective.
• Adjust actuator limit switches. See heading “Limit Switch / Cam Adjustment” on page
Valve position indicator lights
malfunctioning or are com-
pletely defective -
Gear or electric actuator
option.
• Consult separate motorized actuator manual, provided separately with the actuator.
Slow-Close and Electric / Gear Actuator Troubleshooting
Cause / Condition
Remedy
Chart 6a-6: SVS Valve Troubleshooting Chart