wARNING: Do not operate a single line system with the

by-pass plug installed. Operating a single

line system with the by-pass plug installed

will result in damage to the pump shaft seal.

NOTE: Pump pressure was factory pre-set but must

be checked at time of burner start-up. A

pressure gauge is attached to the PRESSURE/

BLEEDER PORT (7) for pressure readings.

Two PIPE CONNECTORS (4) are supplied

with the burner for connection to either a

single or two-line system. Also supplied

are two ADAPTORS (3), two female ¼”

NPT to adapt oil lines to burner pipe

connectors. All pump port threads are British

Parallel Thread design. Direct connection

of NPT threads to the pump will damage the

pump body.

Riello manometers and vacuum gauges do not

require any adapters, and can be safely

connected to the pump ports. An NPT x

metric adapter must be used when connecting

other gauge models.

viii. Replace Burner Cover and Tighten Burner

Cover Screws.

c. Place oil burner gasket on burner and align holes.
d. Remove three (3) 5/16-18 x 3/4 lg. cap screw

from burner swing door used for mounting

burner.

e. Thread (1) 5/16-18 x 3/4 lg. cap screw,

approximately three (3) full turns, into tapping

located at 12:00 o'clock on burner swing door.

f. Insert oil burner into the opening of burner

swing door. Align and engage keyhole slot in

burner flange over head of protruding cap screw

installed in previous Step. Rotate burner to the

right to lock flange behind head of cap screw.

g. Align holes and install two (2) remaining cap

screws. Level burner and fully tighten all three

(3) screws.