beautypg.com

Burnham MEGASTEAM MST288 User Manual

Page 16

background image

16

Figure : Purpose of Tappings and Bosses

TABLE 3: PURPOSE OF TAPPINGS & BOSSES

Tapping

Location

Size, NPT

Boss Location

Thread Size

UNC

Steam Boiler

Less Heater

With Heater

A

¼" - 18

Pressure Gauge

B

¼" - 18

Pressure Limit

C

¾" - 14

Probe LWCO - Std.

Plugged (Float LWCO)

D

½" - 14

Water Gauge Glass (Probe LWCO)

Water Gauge Glass, Pressuretrol &

LWCO (Float LWCO)

E

" - 11½"

Supply (Front & Rear Tappings)

F

¾" - 14

Safety Valve

G

1½" - 11½

Condensate Return

H

1¼" - 11½

Optional Front Return

J

1½" - 11½

Surface Blowoff (Plugged)

K

1" - 11½

Indirect Water Heater Supply

L

½" - 14

Indirect Water Heater Limit

M (4 pcs)

5/16" - 18

Jacket Front Panel, Burner Swing

Door Mounting Bracket

N ( pcs)

3/8" - 16

Burner Swing Door

P (10 pcs)

5/16" - 18

Jacket Rear Panel, Smoke Box Collar,

Cleanout Covers

Q

¼" - 18

Smokebox Pressure Tapping

R

½"-14

L4006

Operating

Control

Plugged