beautypg.com

Burnham MEGASTEAM MST288 User Manual

Page 42

background image

4

TABLE 5: TWO-STAGE UNITS (3450 RPM) -

TWO PIPE SySTEMS

TABLE 6: SINGLE-STAGE UNITS (3450 RPM) -

TWO PIPE SySTEMS

Figure : Two Pipe Oil Lines

C. TwO PIPE OIL LINES

1. For two piped systems, where more lift is required,

the two-stage fuel unit is recommended. Table

5 (two-stage) and Table 6 (single-stage) show

allowable lift and lengths of 3/8 inch and 1/2 inch

OD tubing for both suction and return lines. Refer

to Figure 22.

2. Follow the oil pump manufacturer’s recommenda-

tions on the proper connections for a two pipe

system. Some manufacturers require the insertion

of a bypass plug.

3. Under no circumstances is a manual shutoff valve to

be located on the return line of a two pipe system.

Accidental closure of the return line will rupture the

oil pump seals.

Lift "H"

(See Fig. 22)

Maximum Length of Tubing

"H" + "R" (See Figure 22)

3/8" OD Tubing

(3 GPH)

1/2" OD Tubing

(3 GPH)

0'

93'

100'

2'

85'

100'

4'

77'

100'

6'

69'

100'

8'

60'

100'

10'

52'

100'

12'

44'

100'

14'

36'

100'

16'

27'

100'

18'

---

76'

Lift "H"

(See Fig. 21)

Maximum Length of Tubing

"H" + "R" (See Figure 22)

3/8" OD Tubing

(3 GPH)

1/2" OD Tubing

(3 GPH)

0'

84'

100'

1'

78'

100'

2'

73'

100'

3'

68'

100'

4'

63'

100'

5'

57'

100'

6'

52'

100'

7'

47'

100'

8'

42'

100'

9'

36'

100'

10'

31'

100'

11'

26'

100'

12'

21'

83'

13'

---

62'

14'

---

41'