Bryant 581A/B User Manual
Page 173
173
PHYSICAL DATA — 580F180-300 (cont)
LEGEND
*Circuit 1 uses the lower portion of the condenser coil and lower portion of the evaporator coils;
and Circuit 2 uses the upper portion of both coils.
†Rollout switch is manual reset.
**The 580F300 unit requires 2-in. industrial-grade filters capable of handling face velocities up to 625 ft/min
(such as American Air Filter no. 5700 or equivalent).
NOTE: The 580F180-300 units have a low-pressure switch (standard) located on the suction side.
OPERATING AND RIGGING WEIGHTS
*Base unit weight does not include copper coils, economizer, power exhaust, barometric relief or crating. See
Options and Accessories table below for more information.
NOTE: For 180 or 210 unit, add 75 lb (34 kg) for domestic crating. For 240 unit, add 135 lb (61 kg). For 300
unit, add 175 lb (79 kg) for domestic crating.
OPTIONS AND ACCESSORIES
(Weight Adders)
LEGEND
UNIT 580F
180
210
240
300
FURNACE SECTION
Rollout Switch Cutout Temp (F)†
190
190
190
190
Burner Orifice Diameter (in. ...drill size)
Natural Gas
0.1285...30/0.136...29
0.1285...30/0.136...29
0.1285...30/0.136...29
0.1285...30/0.136...29
Thermostat Heat Anticipator Setting (amps)
208/230, 575 v
Stage 1
0.98
0.98
0.98
0.98
Stage 2
0.44
0.44
0.44
0.44
460 v
Stage 1
0.80
0.80
0.80
0.80
Stage 2
0.44
0.44
0.44
0.44
Gas Input
Stage 1
206,000/270,000
206,000/270,000
206,000/270,000
206,000/270,000
Stage 2
275,000/360,000
275,000/360,000
275,000/360,000
275,000/360,000
Efficiency (Steady-State) (%)
81
81
81
81
Temperature Rise Range
15-45/20-50
15-45/20-50
15-45/20-50
15-45/20-50
Manifold Pressure (in. wg)
Natural Gas
3.3
3.3
3.3
3.3
Gas Valve Quantity
1
1
1
1
Gas Valve Pressure Range
in. wg
5.5-13.5
5.5-13.5
5.5-13.5
5.5-13.5
psig
0.235-0.487
0.235-0.487
0.235-0.487
0.235-0.487
Field Gas Connection Size (in.-FPT)
3
/
4
3
/
4
3
/
4
3
/
4
HIGH-PRESSURE SWITCH (psig)
Cutout
426
Reset (Auto)
320
LOW-PRESSURE SWITCH (psig)
Cutout
27
Reset (Auto)
44
FREEZE PROTECTION THERMOSTAT (F)
Opens
30 ± 5
Closes
45 ± 5
OUTDOOR-AIR INLET SCREENS
Cleanable
Quantity...Size (in.)
2...20 x 25 x 1
1...20 x 20 x 1
RETURN-AIR FILTERS
Throwaway**
Quantity...Size (in.)
4...20 x 20 x 2
4...16 x20 x 2
POWER EXHAUST
1
/
2
Hp, 208/230-460 v Motor Direct Drive, Propeller-Fan (Factory-Wired for 460 v)
Bhp
— Brake Horsepower
TXV
— Thermostatic Expansion Valve
UNIT
BASE UNIT OPERATING WEIGHTS*
180
210
240
300
lb
kg
lb
kg
lb
kg
lb
kg
580F
1800
816
1850
839
1900
862
2270
1030
OPTION/
ACCESSORY
OPTION/ACCESSORY WEIGHTS
180
210
240
300
lb
kg
lb
kg
lb
kg
lb
kg
Barometric Relief Damper
50
23
50
23
50
23
50
23
Power Exhaust
85
39
85
39
85
39
85
39
EconoMi$er IV
90
41
90
41
90
41
90
41
Cu Condenser Coil
150
68
150
68
150
68
150
68
Cu Condenser and Evaporator Coils
280
127
280
127
280
127
280
127
Roof Curb (14-in. curb)
200
91
200
91
200
91
200
91
Horizontal Adapter Curb (Pre-Assembled)
250
113
250
113
250
113
250
113
Horizontal Adapter Curb (Field-Assembled)
348
156
343
156
343
156
343
156
Hail Guard
60
27
60
27
60
27
60
27
Cu — Copper
0TF
Q004
-0
12
58
0F
1
8
0
-30
0