ARI* CAPACITY RATINGS — 581A210-300
LEGEND
*Air Conditioning and Refrigeration Institute.
†IPLV values are calculated based on control configuration T.CTL = 2
(2 Stage Y1).
**Size 300 unit is not listed with ARI, but is tested to ARI standards.
NOTES:
1. Rated in accordance with ARI Standards 360-93 and 270-95.
2. ARI ratings are net values, reflecting the effects of circulating fan heat.
3. Ratings are based on:
Cooling Standard: 80 F db, 67 F wb indoor entering-air temperature and
95 F db air entering outdoor unit.
IPLV Standard: 80 F db, 67 F wb indoor entering-air temperature and 80 F
db outdoor entering-air temperature.
4. All 581A210-300 units are in compliance with ASHRAE 90.1 2001 Energy
Standard for minimum EER requirements. Refer to state and local codes or
visit the following website: http://solstice.crest.org/efficiency/bcap to deter-
mine if compliance with this standard pertains to a given geographical area
of the United States.
HEATING CAPACITIES AND EFFICIENCIES — 581A210-300
VERTICAL SUPPLY — NATURAL GAS
NOTE: All units are 2-stage gas heat.
HORIZONTAL SUPPLY — NATURAL GAS
*7000 cfm minimum recommended above 1.0 in. wg external static pressure.
NOTE: All units are 2-stage gas heat.
VERTICAL SUPPLY — PROPANE
NOTE: All units are 2-stage gas heat.
HORIZONTAL SUPPLY — PROPANE
*7000 cfm minimum recommended above 1.0 in. wg external static pressure.
NOTE: All units are 2-stage gas heat.
UNIT
581A
NOMINAL
TONS
CFM
NET COOLING
CAPACITY (Btuh)
TOTAL
kW
EER
SOUND RATING
(dB)
IPLV†
210
18
5,500
200,000
18.5
10.8
81.7
12.0
240
20
6,000
234,000
21.7
10.8
81.7
11.9
300**
25
7,500
278,000
27.8
10.0
84.6
10.9
db
— Dry Bulb
EER — Energy Efficiency Ratio
IPLV — Integrated Part-Load Values
wb
— Wet Bulb
UNIT
581A
HEATING INPUT
(Btuh) Stage 2/Stage 1
OUTPUT CAPACITY
(Btuh)
TEMPERATURE
RISE (F)
STEADY-STATE
EFFICIENCY %
MINIMUM
HEATING CFM
210250
250,000/199,000
205,000
15-45
82%
4218
210365
365,000/281,000
296,000
25-55
81%
4977
210400
400,000/317,000
328,000
25-55
82%
5522
240250
250,000/199,000
205,000
15-45
82%
4218
240365
365,000/281,000
296,000
25-55
81%
4977
240400
400,000/317,000
328,000
25-55
82%
5522
300250
250,000/199,000
205,000
15-45
82%
4218
300365
365,000/281,000
296,000
25-55
81%
4977
300400
400,000/317,000
328,000
25-55
82%
5522
UNIT
581A
HEATING INPUT
(Btuh) Stage 2/Stage 1
OUTPUT CAPACITY
(Btuh)
TEMPERATURE
RISE (F)
STEADY-STATE
EFFICIENCY %
MINIMUM
HEATING CFM
210250
250,000/199,000
205,000
15-45
82%
4218
210365
365,000/281,000
296,000
25-55
81%
4977
210400
400,000/317,000
328,000
25-55
82%
5522
240250
250,000/199,000
205,000
15-45
82%
4218
240365
365,000/281,000
296,000
25-55
81%
4977
240400
400,000/317,000
328,000
25-55
82%
5522
300250
250,000/199,000
205,000
15-45
82%
4218
300365
365,000/281,000
296,000
25-55
81%
4977*
300400
400,000/317,000
325,000
25-55
82%
5522*
UNIT
581A
HEATING INPUT
(Btuh) Stage 2/Stage 1
OUTPUT CAPACITY
(Btuh)
TEMPERATURE
RISE (F)
STEADY-STATE
EFFICIENCY %
MINIMUM
HEATING CFM
210250
250,000/207,000
205,000
15-45
82%
4218
210365
365,000/291,000
296,000
25-55
81%
4480
210400
400,000/331,000
328,000
25-55
82%
5522
240250
250,000/207,000
205,000
15-45
82%
4218
240365
365,000/291,000
296,000
25-55
81%
4480
240400
400,000/331,000
328,000
25-55
82%
5522
300250
250,000/207,000
205,000
15-45
82%
4218
300365
365,000/291,000
296,000
25-55
81%
4480
300400
400,000/331,000
328,000
25-55
82%
5522
UNIT
581A
HEATING INPUT
(Btuh) Stage 2/Stage 1
OUTPUT CAPACITY
(Btuh)
TEMPERATURE
RISE (F)
STEADY-STATE
EFFICIENCY %
MINIMUM
HEATING CFM
210250
225,000/207,000
185,000
15-45
82%
3807
210365
329,000/291,000
266,000
25-55
81%
4480
210400
356,000/331,000
292,000
25-55
82%
4916
240250
225,000/207,000
184,500
15-45
82%
3796
240365
329,000/291,000
266,000
25-55
81%
4480
240400
356,000/331,000
292,000
25-55
82%
4916
300250
225,000/207,000
185,000
15-45
82%
3807
300365
329,000/291,000
266,000
25-55
81%
4480*
300400
356,000/331,000
292,000
25-55
82%
4920*