Entering Wheel speed calibration (Mode 20)
A 100 meter (328 ft) track is required to perform
wheel speed calibration.
. Drive tractor to the start of the designated test
area .
2 . Stop the tractor 0 m before the start line .
3 . Press and hold the SELECT button () on the Tractor
Performance Monitor (TPM) display for 2 seconds
until TPM displays “” .
4 . Touch the UP arrow button (2) until the TPM
displays “20” .
5 . Press and hold the SELECT button () on the TPM
for 2 seconds until TPM displays “DIST CAL 0” .
6 . Select a low gear and drive the tractor forward .
7 . As the tractor crosses the “Start Line” touch the
SELECT button () once . The TPM will display
“DIST CAL ”
8 . Continue driving until the tractor reaches the
“Finish Line” .