Buhler 535 User Manual
Page 61
3-32
435/485/535
F3-40
F3-39
Fuel Level
The inside right bar graph (3) indicates fuel level .
Each segment of the bar graph display represents
one-twentieth (approximately 5 percent) of the total
fuel content of the tank .
When the fuel level falls so that only two segments of
the bar graph are displayed, the bar graph will flash
continually and the non-critical alarm will sound for
one second .
The system also has a feature to assist the operator
during refueling procedures . An audible indicator
alerts the operator when the tanks are filled to 3/4
capacity (5 bars) and 9/20 or 95% (9 bars) .
NOTE: This feature only operates when the ignition
switch is set to the “RUN” position.
CAUTION: ALWAYS SHUT THE ENGINE OFF DURING
REFUELING PROCEDURES
Battery Volts
The outside right bar graph (4) indicates battery
voltage .
Central Display
Three liquid crystal displays (LCD) are located in the
center of the instrument cluster .
5 . The top LCD is the digital transmission gear shift
position display .
6 . The center LCD is the digital engine speed
display .
7 . The lower LCD will display selected information as
follows:
• Tractor ground speed (MPH or km/h)
• PTO speed (rev/min)
• Engine hours accumulated (actual time)
• Service alert - as required
• Timed exit - as required
3
4
5
6
7
Section 3 - Operation
Electronic Instrument Cluster - EIC