Buhler 535 User Manual
Page 55
3-26
435/485/535
F3-31
F3-30
n/min
RPM
Audible Alarm
An audible alarm will sound under the following
conditions:
• when the ignition is first switched on .
• when a warning light illuminates or a bar graph
indicates a malfunction .
The alarm will alert the operator that a malfunction
has occurred .
Depending on the severity of the malfunction, the
alarm will sound as follows:
Non-Critical Alarm - An audible alarm sounds for one
second only . The tractor will continue to operate, but
the cause of the alarm should be investigated and
corrected .
Critical Alarm - A continuous pulsating tone will
sound until the malfunction is corrected or the engine
is switched off . The engine “STOP” message will flash
in the center display for 30 seconds before automatic
engine shut down occurs . The cause of the malfunction
should be located and corrected immediately to
prevent damage to the tractor .
The audible alarm has a rotary volume control ()
located on the left side of the steering column below
the front controls . Rotate the alarm cover to adjust
the volume .
Automatic Engine Shut Down
An automatic engine shut down feature is standard
equipment . This feature will automatically shut down
the engine within 30 seconds under the following
conditions:
• Transmission oil pressure low
• Engine oil pressure low
• Intake manifold temperature high-critical
• Engine coolant temperature high-critical
• Engine coolant level low
• Electrical charging system voltage low
• Engine oil temperature high-critical
1
WARNING: THE ENGINE SHUT DOWN FEATURE
IS FULLY AUTOMATIC. IT CAN BE OVERRIDDEN
BY THE OPERATOR TO DRIVE THE TRACTOR TO A
SAFE LOCATION. THE OVERRIDE SWITCH IS TO THE
RIGHT OF THE STEERING COLUMN AND SHOULD
ONLY BE USED TO MOVE THE TRACTOR FAR
ENOUGH TO AVOID A DANGEROUS SITUATION.
(See “Engine Shut down Override Switch Operation”
page 3-8) .
Section 3 - Operation
Electronic Instrument Cluster - EIC