1.1.2 Outline of Individual Functions

This section provides an outline of individual functions of HEW.

Fault list display function

It is the function to display fault information of the Agent machine. The information is

stored on the Management Proxy.

(3.3.8 Error Log screen)

Inventory collection function

It is the function to display the inventory of the Agent machine. The following information is

displayed.

RAID controller information (IDE RAID, SCSI RAID)

Product information (RAID, system BIOS, processor, SCSI, Application, etc.)

* Some types of information may not be collected depending on the platform.

(3.3.2 Product Information screen)

(3.3.4 IDE RAID Status screen)

(3.3.5 SCSI RAID Status screen)

Sensor status display function

It is the function to display status information on hardware components including the

power supply or fans and so on.

The supported machine model for an Agent in the status of out-of-band:

MAGNIA Z300/Z310/Z500, MAGNIA3300 (BIOS version 2.0 or more)/3310

(3.3.3 Sensor Status screen)

S.E.L. (System Event Log) function

It is the function to monitor the S.E.L. of the Agent machine. A S.E.L. is a log held on a

motherboard. And the fault information on hardware is mainly recorded on a S.E.L.

The supported machine model for an Agent: MAGNIA Z300/Z310/Z500,

MAGNIA3200/3300/3310

(3.3.11 S.E.L. (System Event Log) screen)

Automatic server restart function

It is the function to automatically reboot the server if the Agent machine is locked. If no

response is received from the system for the specified duration, the function

automatically reboots the Agent machine.

The supported machine model for an Agent:

MAGNIA Z300/Z310/Z500, MAGNIA3200/3300/3310, MAGNIA560S

(3.3.15 Configuration screen)

Remote power control function

Turns on or off the power to the Agent machine from the Management Console.

The supported machine model for an Agent:

MAGNIA Z300/Z310/Z500, MAGNIA3300 (BIOS version 2.0 or more) /3310

(3.3.9 Remote Power Control screen)