TECHNICAL DATA

A

PPL

IA

N

C

E

INF

O

RM

A

T

IO

N

Domestic Hot Water

Min. heat input

KW

7.38

7.38

9.64

9.64

Max. rated heat output

KW

24

28

24

28

Max. rated heat input

KW

24.49

28.57

24.49

28.57

Gas flow rate - Max. 10 minutes from lighting

Natural Gas G20

m

3

/h

2.59

3.02

-

-

Propane Gas (LPG)

kg/h

-

-

1.9

2.22

Max. mains inlet pressure

bar

10

10

10

10

Min. mains inlet pressure (working) for max flow

bar

1.3

1.3

1.3

1.3

Min. mains inlet pressure (working) for operation

bar

0.2

0.2

0.2

0.2

Domestic Hot Water temperature setting

°C

55

55

55

55

Domestic Hot Water specific rate - 30°C rise

l/min

11.5

13.4

11.5

13.4

Max. Domestic Hot Water flow rate - 40°C rise +/— 15%

l/min

8.6

10

8.6

10

Central Heating

Max. rated heat input

KW

24.62

24.62

24.62

24.62

Max. rated heat output 40/30°C

KW

25.67

25.67

25.67

25.67

Max. rated heat output 50/30°C

KW

25.45

25.45

25.45

25.45

Max. rated heat output 80/60°C

KW

24

24

24

24

Max. flow temperature

°C

82

82

82

82

Max. permissible operating pressure

bar

2.5

2.5

2.5

2.5

Available pump head at 21°C system temperature rise

m

2.0

2.0

2.0

2.0

Flue

Flue Gas Temp. 80/60°C, rated/min. load

°C

78/63

78/64

79/64

79/65

Flue Gas Temp. 40/30°C, rated min. load

°C

54/35

54/36

55/38

55/39

CO

2

level at max. rated heat output

%

9.8

9.8

11.0

11.0

CO

2

level at min. rated heat output

%

9.2

9.2

10.5

10.5

NOx - class

5

5

5

5

Condensate

Max. condensation rate

l/h

2.0

2.0

2.0

2.0

pH value, approx.

4.8

4.8

4.8

4.8

Electrical

Electrical power supply voltage

AC...V

230

230

230

230

Frequency

Hz

50

50

50

50

Max. power consumption

W

140

140

140

140

General Data

SEDBUK

band

A

A

A

A

Appliance protection rating

IP

X4D

X4D

X4D

X4D

Appliance protection rating with mechanical or RF mechanical timer fitted IP

20

20

20

20

Permissible ambient temperatures

°C

0-50

0-50

0-50

0-50

Nominal capacity of appliance

Itr

3.9

3.9

3.9

3.9

Noise output level (Max central heating)

dB(A)

42

42

42

42

Packaged boiler weight

kg

44.4

44.4

44.4

44.4

Total boiler weight

kg

39.5

39.5

39.5

39.5

Lift weight

kg

27.1

27.1

27.1

27.1

SEDBUK

%

90.1

90.1

91.8

91.8

DESCRIPTION

NATURAL GAS

L.P.G.

UNITS

24i junior 28i junior

24i junior 28i junior