FAULT FINDING

INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR 24 i junior/28 i junior

8 716 107 336b (11/05)

55

FA

U

LT

F

IN

D

IN

G

& D

IA

G

R

A

M

S

Off

On

Slow flash

(normally off,

flashes on)

Slow flash

(normally on,

flashes off)

Fast flash

Fast flash

2 pulses

5 pulses

Off

Off

Flashing (reset required)

Flashing (reset required)

Off

Flashing

No light

No light

Permanent mains supply to boiler.
Boiler mains switch.
Fuse F1, 2.5A or Fuse F3, 0.5A
Transformer (both coils below 100Ω).
Otherwise replace control board.

Live demand at ST10-L

R

(from external roomstat/timer).

Facia mounted timer (if fitted).
CH knob in winter position.
Diverter valve.
Control board.

Some older thermostats (containing capacitors) may give a low
voltage return at ST10-L

R

when the thermostat contacts are open.

Check that there is not a permanent live at ST10-L

R

from another

source.

See Flow Sensor Test below.
or
Diverter valve.
Control board.

Fan.
Control board.

Gas present and at correct pressure.
Combustion CO2 level.

Flue condition.
Ignition electrodes / harness / connections.
Gas valve (coils 140-190Ω) / low voltage harness connection.
Otherwise replace control board.

Heat exchanger blocked.
Heat exchanger baffles removed and not refitted.

Water pressure.
All air vented.
Pump / harness / connections.
Water leaks / blockages.
Safety thermostats / low voltage wiring harness / connections.
Otherwise replace control board.

Blockage in flue system.

Temperature sensor (8000-20,000Ω).
Low voltage wiring harness / connections to sensor.
Fan / fan harness / connections to fan.
Code plug fitted.

Replace control board

Service mode selected to min, press service button to return to normal.

Service mode selected to max, press service button to return to normal.

NOTE : This fault finding information is for guidance only. Worcester cannot be held responsible for costs incurred by persons not deemed
to be competent.

The electronic control system for this boiler incorporates a blue central indicator. This normally confirms the permanent mains supply but, by
flashing at different rates during a fault, provides a guide to the cause as listed.

This fault finding system assumes that the appliance has been operating normally until the time of failure (i.e. not a first installation error).

PRELIMINARY CHECKS : Preliminary electrical system checks are the first electrical checks to be carried out during a fault-finding
procedure. On completion of the Service/Fault-Finding task which has required the breaking and remaking of electrical connections, check
(a) EARTH CONTINUITY, (b) SHORT CIRCUIT CHECK, (c) POLARITY and (d) RESISTANCE TO EARTH.

FAULT FINDING

Blue light
indication

Lockout reset
button

Possible solution/check

Fault

No power at control board

Boiler not operating during
central heating demand
(HW ok)

Boiler operating
without live demand at
ST10-L

R

(from external

roomstat timer).

Boiler not operating during
hot water demand (CH ok).

Boiler not operating during
any demand.

Ignition lockout

Flue overheat

Heat exchanger overheat

Flue blockage

Volatile lockout

Internal fault

Not a fault code

Not a fault code

Flow Sensor Test
:Replace control board if: 5V is not across the red and black cables.
:1.5V-3.5V is across the yellow and black cables (with water flowing).
Otherwise replace flow sensor.