REPLACEMENT OF PARTS

29. Plastic protection device

Ensure the system is fully drained (see
draining the appliance).
Disconnect all pipes connected to the pump
housing.
Remove the electrical connection to the
pump.
Withdraw the metal clip to the right of the
pump head to release the pump housing.
Slide the device to the left and then withdraw
it from the appliance.

29.1 Remove the spring clip from the pressure

relief valve housing.

29.2 Withdraw the pressure relief valve (A).

To refit, follow the above in reverse. Ensure
any seals that have been disturbed are
renewed.

30. DHW Heat exchanger

Remove the Hydraulic block from the boiler
(See Removing the Hydraulic Block).

30.1 Undo the two screws (B) securing the plastic

housings to the heat exchanger.

30.2 Remove the heat exchanger

To refit, follow the above in reverse. Ensure
any seals that have been disturbed are
renewed.

29.2

A

29.1

30.1

30.2

B