beautypg.com

Flue options – Bosch GREENSTAR 24i junior User Manual

Page 18

background image

FLUE OPTIONS

INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR 24 i junior/28 i junior

8 716 107 336b (11/05)

17

P

R

E -

IN

ST

AL

LA

TI

O

N

FLUE OPTIONS

• The diagrams (opposite) show the

components used and the maximum flue
length for each configuration of 100mm and
125mm flues.

• Shaded flue components indicate the

standard 100mm horizontal flue.

• Only straight flue sections can be reduced in

length and cut.

• The flue terminal end can be fitted from the

inside or outside of the building.

• Fixing kits are supplied with the flue extension

kits.

• Horizontal 125mm and Vertical 100mm and

125mm flue kits are available with separate
instructions. Contact your supplier or
Worcester.

A - Standard horizontal flue (100mm diameter

shown)

B - Straight flue extension

C - Flue bend 90°

D - Flue bend 45°

E - Vertical terminal (vertical adaptor supplied

with terminal)

F - Vertical adaptor (used with horizontal

terminal)

Calculating the flue length:
Measure the total flue length required, noting
that the maximum straight flue length including
the terminal is:
Horizontal 60/100mm: 4600mm
Horizontal 80/125mm: 13000mm
Vertical 60/100mm: 6400mm
Vertical 80/125mm: 15000mm

Then reduce the total straight flue length for
each extra flue bend (excluding the flue elbow)
by:
2000mm for 90°
1000mm for 45°

Flue Extension lengths:
Horizontal & Vertical 60/100mm: 960mm
Horizontal & Vertical 80/125mm: 1000mm

Flue Terminal lengths:
Horizontal 60/100mm: 800mm including terminal
Horizontal 80/125mm: 1200mm including terminal
Vertical 60/100mm: 1140mm to top of terminal
Vertical 80/125mm: 1365mm to top of terminal

STANDARD FLUE HORIZONTAL

Ø100
MAX 686 A x 1
MIN 250 A x 1*

Ø125
MAX 1070 A x 1
MIN 250 A x 1*
* Requires cutting

MAXIMUM FLUE HORIZONTAL

Ø100 - 4600mm

A x 1 + B x 5

Ø125 - 13000mm
A x 1 + B x 13

MAXIMUM FLUE VERTICAL START + 1 BEND

Ø100 - 4600mm
A x 1 + C x 1 + B x 5 +
F x 1

Ø125 - 13000mm
A x 1 + C x 1 + B x 13 +
F x 1

Ø100 - 2600mm

A x 1 + B x 3 + C x 1

Ø125 - 11000mm
A x 1 + B x 11 + C x 1

MAXIMUM FLUE HORIZONTAL + 1 BEND

MAXIMUM FLUE VERTICAL
START + 2 BENDS

Ø100 - 2600mm

A x 1 + C x 2 + B x 4 +

F x 1

Ø125 - 11000mm
A x 1 + C x 2 + B x 13 +
F x 1

Ø100 - N/A

Ø125 - 9000mm
A x 1 + C x 3 + B x 11 +
F x 1

MAXIMUM FLUE VERTICAL
WITH 2 x 45° BENDS

Ø100 - 4400mm
(including terminal)
B x 5 + D x 2 + E x 1

Ø125 - 13000mm
(including terminal)
B x 13 + D X 2 + E x 1

Ø100 - 2400mm

(including terminal)

B x 4 + C x 2 + E x 1

Ø125 - 11000mm
(including terminal)
B x 13 + C x 2 + E x 1

VERTICAL FLUE WITH
2 x 90° BENDS

A

A

B

A

B

F

C

A

B

C

F
B

C

A

F
B

C

A

E

B

D

E

B

C

MAXIMUM FLUE VERTICAL
START + 3 BENDS

This manual is related to the following products: