REPLACEMENT OF PARTS

19. Diverter valve motor

Insure the appliance is in service mode
(there is no need to drain the appliance).
Disconnect the electrical connector from the
diverter valve motor.

18.1 Pull the motor assembly (A) towards you. The

assembly will slide free from the valve.
To refit, follow the above in reverse.

20. Diverter valve

Ensure the appliance has been fully drained.
Disconnect the electrical connector from the
diverter valve motor.
Undo the two screws holding the valve to the
plastic housing.

20.1 Withdraw the valve (B) and clean the valve

chamber if necessary.
To refit, follow the above in reverse. Ensure
any seals that have been disturbed are
renewed.

21. Auto air vent

Ensure the appliance has been fully drained.

21.1 Use a screwdriver or similar to rotate the air

vent anticlockwise.

21.2 Lift the air vent (C) out of the housing and

remove.
To refit, follow the above in reverse.

22. DHW temperature sensor

Ensure the domestic hot water circuit is fully
drained (see draining the domestic hot water).
Disconnect the electrical connection from
the sensor.

22.1 Withdraw the spring clip.
22.2 Withdraw the sensor (D) from the housing.

To refit, follow the above in reverse.

19.1

A

21.2

C

20.1

B

22.2

D

22.1

REPLACEMENT OF PARTS

INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR 24 i junior/28 i junior

8 716 107 336b (11/05)

47

SER

V

IC

IN

G

&

SP

A

RES

21.1

This manual is related to the following products: