beautypg.com

L. p. g. conversion – Bosch GREENSTAR 24i junior User Manual

Page 55

background image

1.1

1.2

A

2.2

2.3

2.1

3

C

B

TH E GAS / AI R R ATI O M U ST B E
R ESET AFTE R CONVE R SION. TH E
P R O C E D U R E C AN B E F O U N D I N
THE REPLACEMENT PARTS SECTION
OF THIS MANUAL.

4.1

4.2

D

E

A

L. P. G. CONVERSION

L.P.G. CONVERSION

INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR 24 i junior/28 i junior
8 716 107 336b (11/05)

54

C

O

NVE

R

S

IO

N

K

ITS

Important: The appliance shall not be installed
into a room or internal space below ground
level when it is intended for use with LPG
(propane - G31). This does not preclude the
installation into a room or space which is a
basement on one side of the building but open
to ground on the opposite side.

Installation Regulations
In addition to those specified in the main
booklet the following standard applies when
converting to an LPG appliance: BS 5842
Domest ic Propane Gas Burning
Installations.

All conversions will require the air gas ratio to
be set correct ly for t he gas used . The
procedure for setting the air gas ratio is at
the rear of these instructions.

1. Moving boiler control to service
position

Remove boiler case, as described on page
36.

1.1 Remove screw (A) from retaining bracket.
1.2 Lower control panel into service position.

2. Gas valve

Isolate gas supply at boiler gas cock.

2.1 Remove wire clip from gas valve outlet then

pull gas adjustment assembly free from
plastic connector and pull forward clear of
case.

2.2 Undo bottom gas connection to gas valve.
2.3 Undo two securing screws (B) on the

underside of casing.
Pull valve up and forward out of boiler.
Disconnect electrical connections.
Fit plastic retaining nut to the outlet of the
gas valve from the kit and hand tighten.
Replace valve with new seals.
Check for gas soundness.

3. Gas adjuster

Twist retaining clip (C) to release then
remove clip and tube.
Refit new adjuster and secure with clip.
Coloured red for LPG or black for NG.

4. Code plug

4.1 Remove 3 screws (D) retaining plastic

cover at rear of control box and remove.

4.2 Replace code plug (E) with new one

supplied with conversion kit.
Replace plastic cover.
Place control in normal position and secure
with screw.

I S O LATE MAI N S E LE CTR I C AL
SUPPLY AND REMOVE OUTER CASE
AS SHOWN IN THE INSTALLATION,
C O M M I S S I O N I N G & S E RVI C I N G
INSTRUCTIONS

THE CONVERSION MUST BE CARRIED OUT
BY A COM PETE NT PE R SON. IT M UST NOT
B E AT T E M P T E D U N L E S S T H E P E R S O N
C A R R Y I N G O U T T H E C O N V E R S I O N I S
EQUIPPED WITH A COMBUSTION ANALYSER
C O N F O R M I N G TO B S 79 2 7 A N D I S
COMPETENT IN IT’S USE.

Code plugs

24kW NG

-

100

24kW LPG

-

101

28kW NG

-

102

28kW LPG

-

103