ELECTRICS

A

1

2

B

ELECTRICS

INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR 24 i junior/28 i junior

8 716 107 336b (11/05)

27

IN

ST

AL

LA

TI

O

N

CAUTION: ISOLATE THE MAINS

ELECTRICITY SUPPLY BEFORE STARTING

ANY WORK AND OBSERVE ALL

RELEVANT SAFETY PRECAUTIONS

Mains supply to the boiler must be through a
fused double pole isolator situated adjacent
to the appliance. The isolator must have a
contact separation of 3mm minimum in all
poles. External fuse rating 3A.

When stripping wires always ensure copper
strands do not fall into the control box.

Access to electrical connections:
Remove boiler casing to access control panel.
1 Unscrew screw (A) and lower the control

box into the horizontal position.

2 Unscrew the three screws (B) in the control

panel and pull off the connections cover.

3 Unclip cable clamp (C).
4 Cut off the tapered cable entry to fit cable

diameter required.

5 Turn cable retaining screw (D) anti-clockwise.

Run cable over the main crossbar and
through the cable clamp (C), ensuring there
is ample cable to reach the connectors.
Turn cable clamping screw (D) clockwise to
secure cable.
After wiring to connectors is complete, snap
cable clamp (C) into control box.

6 Mains power 230v connection (ST10):

Separate wires from cable end and

strip to 6mm

Connect LIVE wire to terminal (L)
Connect NEUTRAL wire to the terminal (N)
Connect EARTH wire to the bracket

NOTE: Earth cable to be longer so that it pulls
out last if mains cable is snagged.

7 230V room stat/clock (ST10):
The diagram shows the option of roomstat with
programmer or roomstat only.

Remove link.
Connect LIVE supply to terminal (L

S

).

Connect SWITCHED LIVE to terminal (L

R

),

NOTE: This is sometimes refered to as ‘call for

heat’ or ‘heating load’.

Connect NEUTRAL to terminal (N

S

).

NOTE: Some devices do not require this.

8 Optional external frost stat connection (ST6):

Connect froststat cables to terminals (FS) and
(FR). These are not polarity sensitive.

9 Refit

panels.

3

C

4

5

D

6

7

8

F1

F3

F2

ROOMSTAT
ONLY

PROGRAMMER

ROOMSTAT
AND
PROGRAMMER

ROOMSTAT

230V

MAINS

SUPPLY

ST6

ST10

eart

h

swit

ched live

live

neut

ral

blue

green/yellow

brown

FROSTSTAT